NTP over Management VRF Limitations
Be aware of the following limitations before implementing NTP over Management VRF.
-
Please confirm.NTP over Management VRF is not supported on ICX 7150 and ICX 8200 devices.
- The communication channel between the NTP client and the server is through the In-Band data port only. An Out-Of-Band (OOB) management port is not supported.
- One external NTP server must exist to synchronize an NTP client with an NTP server.
- If you configure NTP in a VRF, ensure that the NTP server and clients can reach each other through the configured VRFs.
- A source interface must be configured to support the management VRF.
- The management VRF for NTP broadcast clients is
supported only on one interface, using the
management source-interface protocol ntpcommand, because the outgoing port is determined by the routing table. - The management VRF for peers is supported only on
“symmetric active” (not "symmetric passive") NTP association modes because the
management VRF is related to the NTP
management source-interface protocol ntpcommand.