ACL Logging Upgrade Considerations
Last Updated
Sep 03, 2026
the respective bindings corresponding to the filter group and interface combination in the ingress direction after the upgrade. On RUCKUS ICX 7150, ICX 7550, ICX 7650, and ICX 7850 devices, ACL logging is not supported for ACLs applied to outbound traffic.
-
Configuration Notes for ACL Logging
Last Updated
Sep 03, 2026
, RUCKUS ICX 7650, RUCKUS ICX 7750, and RUCKUS ICX 7850 devices, ACL logging is not supported for ACLs applied to outbound traffic. In a rule that includes one or more of the following parameters, the log keyword is ignored: dscp-matching dscp-marking 802.1p-priority-matching 802.1p-priority-marking
-
Campus Fabric topology overview
Last Updated
Sep 03, 2026
combination of ICX 7150, ICX 7250, or ICX 7450 units. In the following figure, four ICX 7650 units are configured in a ring stack form the CB. Three of the CB units are connected to PE units (SPX 17, 18, and 19). Control bridge ring with attached PE (SPX) units In the following figure, three of the ICX 7650 CB
-
Campus Fabric Topology Overview
Last Updated
Sep 03, 2026
ICX 7650, ICX 7750, or ICX 7850 units connected in a linear or ring topology. PE units are specially configured ICX 7450, ICX 7250, or ICX 7150 units that are connected to the CB. The PE units can be connected to each other over a single SPX port or LAG to form a PE chain or ring. The PE chain or
-
qos priority-to-pg
Last Updated
Sep 03, 2026
. Global configuration mode This command is not supported on Ruckus ICX 7150 or ICX 7650 devices. This command is not supported for RUCKUS ICX 8200, ICX 7150, or ICX 7650 devices. You must configure the priority-flow-control enable command to enable PFC globally before you configure priority-to-PG
-
Adding a Stack
Last Updated
Sep 22, 2026
firmware. The supported models for Stacking are: All members must be from the same ICX family (for example, ICX 7150, ICX 7550, ICX 7650, ICX 7850, ICX 8100, or ICX 8200); different models within that family can be stacked (for example, ICX8200‑24FX with ICX8200‑48PF). ICX 7150: ICX 7150 stacks support up
-
sflow sample
Last Updated
Sep 03, 2026
resources. Using a low denominator for the sampling rate can cause high CPU utilization. On RUCKUS ICX 7750, ICX 7450, ICX 7250, ICX 7650, ICX 7850, and ICX 7550 the CPU-bound sFlow sample packets are rate-limited to 50 samples per second to avoid high CPU utilization. On RUCKUS ICX 7450, ICX 7250, ICX 7650, ICX
-
Locating a Device Using Port LEDs
Last Updated
Sep 03, 2026
LED status. The default LED status behavior also applies after the device is rebooted when all port LEDs are turned on using the led on command. The LED ON/OFF feature is supported only on the platforms where LED status mode is available. The status mode is supported on ICX 7550, ICX 7650, ICX 7850
-
Locating a Device Using Port LEDs
Last Updated
Sep 03, 2026
LED status. The default LED status behavior also applies after the device is rebooted when all port LEDs are turned on using the led on command. The LED ON/OFF feature is supported only on the platforms where LED status mode is available. The status mode is supported on the ICX 7150, ICX 7650, ICX
-
qos priority-to-pg
Last Updated
Sep 03, 2026
. Global configuration mode This command is supported only on Ruckus ICX 7250, ICX 7750, and ICX 7450 devices. This command is not supported on Ruckus ICX 7150 or ICX 7650 devices. You must configure the priority-flow-control enable command to enable PFC globally before you configure priority-to-PG