Long-Distance Stacking Ports
Last Updated
Sep 03, 2026
devices are configured in stacking mode, front panel slot 2 also supports 2 X 40-Gbps or 1 X 100-Gbps modules with their respective RUCKUS-qualified optical hardware. 1/3/1, 1/3/2 ICX 7850-32Q 1/2/1 through 1/2/12, 1/3/1 through 1/3/8 1/3/1 through 1/3/8 ICX 7850-48F/48FS 1/2/1 through 1/2/8 1/2/1
-
optical-monitor
Last Updated
Sep 03, 2026
no optical-monitor non-ruckus-optic-enable Optical transceivers are not monitored. alarm-interval Specifies the interval at which alarms and warning messages are sent. The default and minimum timer for ICX 7450, ICX 7550, ICX 7650, RUCKUS ICX 7750, and ICX 7850 devices is 8 minutes. The default
-
Authentication Session Limits on an Interface
Last Updated
Sep 03, 2026
Port When None of the Clients Has Dynamic ACL Maximum Number of MAC Sessions per Port When at Least One Client Has Dynamic ACL ICX 8200 1024 32 ICX 8100 1024 32 ICX 7850 1024 32 ICX 7650 1024 32 ICX 7550 1024 32 ICX 7150 1024 32 ICX 7150-ES Models 256 2 The system limit for authenticated MAC
-
Authentication Session Limits on an Interface
Last Updated
Sep 03, 2026
Port When None of the Clients Has Dynamic ACL Maximum Number of MAC Sessions per Port When at Least One Client Has Dynamic ACL ICX 8200 1024 32 ICX 8100 1024 32 ICX 7850 1024 32 ICX 7650 1024 32 ICX 7550 1024 32 ICX 7150 1024 32 ICX 7150-ES Models 256 2 The system limit for authenticated MAC
-
optical-monitor
Last Updated
Sep 03, 2026
no optical-monitor non-ruckus-optic-enable Optical transceivers are not monitored. alarm-interval Specifies the interval at which alarms and warning messages are sent. The default and minimum timer for ICX 7450, ICX 7550, ICX 7650, RUCKUS ICX 7750, and ICX 7850 devices is 8 minutes. The default
-
optical-monitor
Last Updated
Sep 03, 2026
no optical-monitor non-ruckus-optic-enable Optical transceivers are not monitored. alarm-interval Specifies the interval at which alarms and warning messages are sent. The default and minimum timer for ICX 7450, ICX 7550, ICX 7650, RUCKUS ICX 7750, and ICX 7850 devices is 8 minutes. The default
-
VRRPv2 - Virtual Router Redundancy Protocol Version 2
Last Updated
Sep 03, 2026
VRRPv2 - Virtual Router Redundancy Protocol Version 2 VRRPv2 - Virtual Router Redundancy Protocol Version 2 VRRPv2 - Virtual Router Redundancy Protocol Version 2 Feature ICX 7150 ICX 7250 ICX 7450 ICX 7550 ICX 7650 ICX 7850 Virtual Router Redundancy Protocol (VRRP) 08.0.61 08.0.30 08.0.20 08.0.95
-
RADIUS
Last Updated
Sep 03, 2026
RADIUS RADIUS RADIUS Feature ICX 7150 ICX 7250 ICX 7450 ICX 7550 ICX 7650 ICX 7850 RADIUS 08.0.60 08.0.30 08.0.20 08.0.95 08.0.70 08.0.90 RADIUS Change of Authorization (CoA) 08.0.60 08.0.30 08.0.20 08.0.95 08.0.70 08.0.90 CoA extended options: Vendor-specific Foundry-COA-Command attribute for
-
BGP4+ - IPv6 Border Gateway Protocol
Last Updated
Sep 03, 2026
BGP4+ - IPv6 Border Gateway Protocol BGP4+ - IPv6 Border Gateway Protocol BGP4+ - IPv6 Border Gateway Protocol Feature ICX 7150 ICX 7150-ES ICX 7550 ICX 7650 ICX 7850 ICX 8100 ICX 8200 BGP4+ No No 08.0.95 08.0.70 08.0.90 No No Configuring BGP4+ Neighbors Using Global or Link-Local IPv6 Addresses No
-
ARP - Address Resolution Protocol
Last Updated
Sep 03, 2026
ARP - Address Resolution Protocol ARP - Address Resolution Protocol ARP - Address Resolution Protocol Feature ICX 7150 ICX 7150-ES ICX 7550 ICX 7650 ICX 7850 ICX 8100 ICX 8200 Static ARP entries 08.0.60 10.0.10d 08.0.95 08.0.70 08.0.90 10.0.10f 10.0.00 Configurable ARP priority 08.0.60 10.0.10d