    Last Updated Sep 03, 2026

    allows you to prevent the shutdown of ICX 8100 and ICX 8200 devices when the temperature of the box breaches the warning or shutdown threshold. This is intended to be used in emergency conditions to allow the switches to function in a hostile environment as long as possible.
  • Power Consumption (Maximum Configuration) Alternating-Current (AC)

    Last Updated Sep 02, 2026

    % PoE load on PoE models. Fans are at high speed. Part Number (Input Power +/-5%) @100 VAC Input @200 VAC Input Minimum Number of Power Supplies ICX8100-C08PF 154.2 W 526.3 BTU/hr 150.6 W 514.01 BTU/hr 1PSU ICX8100-C08PF-V 154.2 W 526.3 BTU/hr 150.6 W 514.01 BTU/hr 1PSU ICX 8100-C16P 157 W 543.3 BTU/hr
  • Stack Management

    Last Updated Sep 03, 2026

    Trunks in a Live Environment Configuring Stacking Ports in a Live Environment Handling Stack-Port and Stack-Trunk Mismatches in ICX 8100 and ICX 8200 When a stack-port is incorrectly connected to a stack-trunk, the system monitors and restores port status once the mismatch is resolved—either through
  • tunnel path-mtu-discovery

    Last Updated Sep 03, 2026

    Disables PMTUD. Tunnel interface configuration mode ICX 7150 and ICX 8100 devices do not support tunnels. The no form of the command disables PMTUD and resets the aging to the default value of 10 minutes. The following example changes the reset time (default age timer) to a value of 25. device
  • LLDP - Link Layer Discovery Protocol

    Last Updated Sep 03, 2026

    LLDP - Link Layer Discovery Protocol LLDP - Link Layer Discovery Protocol LLDP - Link Layer Discovery Protocol Feature ICX 7550 ICX 7650 ICX 7850 ICX 8100 ICX 8200 LLDP 08.0.95 08.0.70 08.0.90 10.0.10f 10.0.00 LLDP-MED 08.0.95 08.0.70 08.0.90 10.0.10f 10.0.00 Support for tagged LLDP packets 08.0.95
  • erase system factory-default

    Last Updated Sep 03, 2026

    partitions. This option is only supported on ICX 8100 and ICX 8200 devices. Global configuration mode The erase system factory-default command resets the switch to its original state and boots from the currently installed UFI image in the primary partition. Autocomplete is disabled for this command. You
  • ip multicast mvr

    Last Updated Sep 03, 2026

    MVR for specified groups, use the ip multicast mvr mvlan command. On ICX 8100 devices, MVR processes IGMPv3 join messages on receiver VLANs only if IGMPv3 is enabled globally using the ip igmp version 3 command. The no form of the command removes all MVR configurations. To disable MVR on a specific
  • Configuration Notes and Feature Limitations for IPv6 Source Guard

    Last Updated Sep 03, 2026

    the same device, as long as they are not configured on the same port or VLAN. IPSGv6 can be enabled on tagged or untagged ports in a VLAN but cannot be configured globally for a VLAN. IPSGv6 can be configured on a maximum of 511 VLANs. IPSGv6 and IPSGv6 ACLs are supported together on the same ICX 8100 or
  • Others

    Last Updated Sep 02, 2026

  • Layer 2 Multicast Scaling

    Last Updated Sep 03, 2026

    Layer 2 Multicast Scaling Layer 2 Multicast Scaling Layer 2 Multicast Scaling ICX 7150 ICX 7150-ES ICX 7550 ICX 7650 ICX 7850 ICX 8100 ICX 8200 IGMP Groups 3,072 3,072 Profile 1: 6,144 Profile 2: 6,144 Profile 3: 6,144 8,000 Profile 1: 6,144 Profile 2: 6,144 Profile 3: 8,192 Profile 4: 6,144