Relevance: best match to your search term first.

  • SPX Port and LAG Configuration Rules

    Last Updated Sep 03, 2026

    , after first checking that the PE unit will still be reachable once the configuration changes. PE units further downstream are not guaranteed to remain reachable after the reserve configuration is pushed to the PE unit. When the spx pe-enable command is entered locally on an ICX 7150, ICX 7250, or ICX
  • show hardware ipv6-route

    Last Updated Sep 03, 2026

    intf: 511 RouteHit: No, (pkt_count=0, devId/pcl=0/76, 1/89) Release Command History 08.0.61 This command was introduced for the ICX 7150 and output was modified. 08.0.95 This command was modified to display the status of the IPv6 hardware routes.
  • Prerequisites

    Last Updated Sep 03, 2026

    switches (also called "edge switches") switches: RUCKUS ICX 7150, RUCKUS ICX 7250, RUCKUS ICX 7450, RUCKUS ICX 7550, RUCKUS ICX 7650, or RUCKUS ICX 7850. Also, see "ICX Switch Preparation for Network Segmentation" below. Required systems: Cloudpath server installed. vSZ controller installed and the
  • SPX port and LAG configuration rules

    Last Updated Sep 03, 2026

    , after first checking that the PE unit will still be reachable once the configuration changes. PE units further downstream are not guaranteed to remain reachable after the reserve configuration is pushed to the PE unit. When the spx pe-enable command is entered locally on an ICX 7150, ICX 7250, or ICX
  • Setting the clock parameters for the device

    Last Updated Sep 03, 2026

    in Real Time Clock(RTC) register even when power is removed from the device. However, ICX 7150 and ICX 7650 do not have this capability because they were designed without RTC battery, therefore they do not retain clock date and time in case of power outage. To avoid this, you should configure NTP
  • System-Max Changes and uRPF

    Last Updated Sep 03, 2026

    System-Max Changes and uRPF System-Max Changes and uRPF System-Max Changes and uRPF The following tables describe the system-max values with and without uRPF configured on the device. Note that the values with uRPF configuration after reload are reduced by half. uRPF is not supported on the ICX
  • SPX configuration unit table

    Last Updated Sep 03, 2026

    SPX configuration unit table SPX configuration unit table SPX configuration unit table The following MIB table objects display CB and PE units in an SPX system and configure SPX-related information for each PE unit. The following table objects are supported only on the Ruckus ICX 7150, Brocade ICX
  • SPX global scalar MIB objects

    Last Updated Sep 03, 2026

    SPX global scalar MIB objects SPX global scalar MIB objects SPX global scalar MIB objects The following Switch Port Extender (SPX) global scalar objects are supported on the Ruckus ICX 7150, Brocade ICX 7250, Brocade ICX 7450, RUCKUS ICX 7650 or Brocade ICX 7750 devices depending on the role of the
  • Checking the Cloud Connection Status

    Last Updated Sep 03, 2026

    Checking the Cloud Connection Status Checking the Cloud Connection Status Checking the Cloud Connection Status ICX 7150, ICX 7650, and ICX 7850 switches have an LED that indicates when the device is managed from the cloud. The following table interprets the LED status. Refer to the FastIron
  • Applying ACLs to rate limit inbound CPU traffic

    Last Updated Sep 03, 2026

    . In an ICX device that has two packet processors, for example, ICX 7450-32P, ICX 7450-48P, or ICX 7150-48P devices, an ACL applied on the CPU port is applied in both packet processors. The deny any any statement is not supported for ACLs applied to the CPU. ACLs applied to the CPU do not support