High Availability Active-Active Deployment Model
This feature requires a minimum of two nodes and a maximum of four nodes in a cluster. The Active-Active HA mode is designed to provide both redundancy and scalability. In this mode, all cluster nodes can simultaneously manage tunnels from APs.
If the SDLAN service is enabled on the Edge cluster in Active-Active HA mode, RUCKUS One will provide APs with a list of Edge VXLAN Tunnel Endpoint (VTEP) IP addresses. This list includes the IP address of each node in the cluster.
To distribute the load of AP tunnels across all nodes in the Active-Active HA mode cluster, two load distribution methods are supported.
- Random distribution: Each AP randomizes the Edge VTEP IP address list using its serial number as a random seed. Each AP will then attempt to connect to the first Edge IP address in its randomized list, known as the primary Edge. This approach directs the tunnels from APs to different nodes in the Active-Active HA cluster, effectively distributing the load.
- Per AP-group distribution: Each AP randomizes the Edge VTEP IP address list using the AP-group identifier. In this method, all APs in the same AP-group will derive same randomized IP list. As each AP will attempt to connect to the first Edge IP address in its randomized list, all APs in same AP-group tunnel to same Edge node. As long a wireless client roam across APs in same AP-group, there will not be any MAC movement for that wireless client MAC address in the Edge uplink port switch network.
In High Availability, if an AP is unable to connect to the first Edge IP address in its randomized list, it will attempt to connect to the next IP address in the list. If it cannot connect to the last IP address in the list, it will try the first IP address again. The AP will continue this process until it successfully connects to an Edge device. The Edge to which the AP connects is referred to as the active Edge.
When an AP is connected to an Edge node, it will continuously send periodic keepalive traffic to ensure the Edge is reachable. If the keepalive to the active Edge fails, the AP will attempt to connect to the next Edge in the list. This process is known as AP tunnel failover to the next Edge.
Services Supported for High Availability Active-Standby Deployment Model
This section describes the services supported for High Availability.
Failure and Expected Behavior
Whenever a node fails, all the APs which are tunneling to that node, will start tunneling to other available nodes in the cluster.
LAN, Node and Cluster Link Failure and Expected Behavior - AA HA
| Failure Type | Failure Behavior | Failure Recovery Behavior |
|---|---|---|
| LAN Failure | In this case, APs which are tunneling to this node, will start tunneling to other available nodes in the cluster. | After the network or link failure is rectified, node joins back the cluster. |
| Node Failure | In this case, APs which are tunneling to this node, will start tunneling to other available nodes in the cluster. | After the node initializes, it rejoins the cluster. |