Resolving Module 3 Mismatches in a Standalone RUCKUS ICX 7550 Switch
Use the following procedure to resolve a Module 3 configuration mismatch for a RUCKUS ICX 7550 switch in standalone mode.
- Power down the switch, replace the installed module, and then reboot the switch.
- Use the no module command to remove the current
Module 3 configuration.
device(config-unit-1)# no module 3 icx7600-xgf-4port-40g-module icx7600-100g-1port-100g-module icx7600-qsfp-2port-80g-module icx7600-xgf-4port-40g-module
- Configure Module 3 for the installed module.
device(config-unit-1)# module 3 icx7600-xgf-4port-40g-module icx7600-100g-1port-100g-module icx7600-qsfp-2port-80g-module icx7600-xgf-4port-40g-module
- Use the write memory command and then check the
configuration with the show config
command.
device# sh conf ! Startup-config data location is flash memory ! Startup configuration: ! ver 08.0.95_b1555T243 ! stack unit 1 module 1 icx7550-24p-port-management-module module 2 icx7550-qsfp-2port-80g-module module 3 icx7600-xgf-4port-40g-module stack-port 1/2/1 stack-port 1/2/2 !