Digital Optical Monitoring
You can configure your RUCKUS device to monitor optical transceivers in the system, either globally or by specified ports. When DOM is enabled, the system monitors the temperature and signal power levels for the optical transceivers in the specified ports. Console messages and syslog messages are triggered when optical operating conditions fall below or rise above the SFP, SFP28, SFP+, QSFP, QSFP+, and QSFP28 manufacturer-recommended thresholds.
For a list of supported media types, refer to the Ruckus Ethernet Optics data sheet.
Beginning with FastIron release 08.0.95, new RUCKUS optic has been introduced for ICX 7650 and ICX 7550. The new 100G-ER4 (Extended Reach 4 Lanes) or 100G-ER4-Lite optic do not support stacking ports. They support 40km transmission with Forward-Error-Correction (FEC) and 30km transmission without FEC.
The show media ethernet command is used
to display information about the media device installed in a port.
ICX7550-24F Switch# show media ethernet 1/1/1
Port 1/1/1: Type : 100GBASE-ER4 40km (QSFP28)
Vendor: RUCKUS Version: A
Part# : 57-1000489-01 Serial#: YFK119452000012
Display the optical monitoring information using
the show optic command.
ICX7550-24F Switch# show optic 1/2/1
100GBASE-ER4
===============
Port Temperature Voltage Tx Power Rx Power Tx Bias Current
+-----+-------------+-------------+-------------+-------------+---------------+
1/2/1 31.7773 C 3.1911 volts 000.7309 dBm -015.6224 dBm 59.932 mA
Normal Normal Normal Normal Normal
Chan Rx Power #1 Rx Power #2 Rx Power #3 Rx Power #4
+----+-----------+--------------+--------------+---------------+
-015.6224 dBm -015.3165 dBm -015.1427 dBm -015.2143 dBm
Normal Normal Normal Normal
Chan Tx Bias #1 Tx Bias #2 Tx Bias #3 Tx Bias #4
+----+-----------+--------------+--------------+---------------+
59.932 mA 57.544 mA 60.216 mA 59.932 mA
Normal Normal Normal Normal
Chan Tx Power #1 Tx Power #2 Tx Power #3 Tx Power #4
+----+-----------+--------------+--------------+---------------+
000.7309 dBm 000.4575 dBm 000.5530 dBm 000.4626 dBm
Normal Normal Normal Normal
The 100G-PAM4 optic supports RUCKUS ICX 7850, ICX 7650 and ICX 7550 with new 100G or 200G or 400G standard. They support uplink ports only. The maximum transmission distance for 100G-DR or 100G-DR1 is 500m. DR1 represents one lane with 100G. The maximum transmission distance for 100G-FR or 100G-FR1 is 2km. The maximum transmission distance for 100G-LR or 100G-LR1 is 10km.
ICX7850-32Q Router# show media ethernet 1/3/5
Port 1/3/5: Type : 100GBASE-DR PAM4 500m (QSFP28)
Vendor: RUCKUS Version: A
Part# : 57-1000488-01 Serial#: YTK11950T000003
ICX7850-32Q Router# show optic 1/3/5
100GBASE-DR
==================
Port Temperature Voltage Tx Power Rx Power Tx Bias Current
+-----+-------------+-------------+-------------+-------------+---------------+
1/3/5 31.0742 C 3.1667 volts 001.0157 dBm 001.6725 dBm 72.000 mA
Normal Normal Normal Normal Normal