Enabling DOM

Complete the following steps to enable DOM.
Note: DOM is supported only on RUCKUS optics.
  1. Use the optical-monitor command to enable digital optical monitoring, and specify the polling and alarm interval. Enter one of the following versions of the command:
    • Enable digital optical monitoring and specify an alarm interval.

      device(config)# optical-monitor 18
      Enable optical monitoring and set alarm/warn interval to 18 minute(s) 
      

    • Enable digital optical monitoring, without specifying an alarm interval, to set the alarm interval to the default. The following example is for ICX 7150 devices. The default alarm interval for ICX 7150 is 3 minutes.
      device(config)# optical-monitor 
      Enabled optical monitoring and set alarm/warn interval to default(3 minutes)
      

      The default alarm interval for ICX 7550, ICX 7650, ICX 7850, and RUCKUS ICX 8200 devices is 8 minutes.

      device(config)# optical-monitor 
      Enable optical monitoring and set alarm/warn interval to default(8 minutes)
      

    Ports that are down are not included for optical monitoring by default configuration. To allow the monitoring for the down ports on an ICX device, enter the optical-monitor down-port-enable command.

  2. Use the interface command, specifying an interface, to enter interface configuration mode for the specified interface.
    device(config)# interface ethernet 1/1/1
    
  3. Use the optical-monitor command, without specifying a value, to enable optical monitoring on the specified port and set the default polling and alarm interval.
    device(config-if-e10000-1/1/1)# optical-monitor
    
  4. Use the exit command to return to global configuration mode.
    device(config-if-e10000-1/1/1)# exit
    
  5. Use the interface command, specifying a range of interfaces, to specify a range of interfaces.
    device(config)# interface ethernet 1/1/1 to 1/1/2
    
  6. Use the optical-monitor command, without specifying a value, to enable optical monitoring on the specified range of ports and set the default polling and alarm interval.
    device(config-mif-e10000-1/1/1-1/1/2)# optical-monitor
    
  7. Use the exit command to return to global configuration mode.
    device(config-mif-e10000-1/1/1-1/1/2)# exit
    
  8. Verify the alarm and warning interval.
    device(config)# show optic-timer 1/1/4 
    
    Optical monitoring timer Interval for Port 1/1/4 is 8 mins
    
  9. Verify the media device configuration.
    1. Display information about the media devices installed per device, per stack, and per port.
      device(config)# show media 
      
      Port 1/1/1:	 Type : 1G M-C (Gig-Copper)
      Port 1/1/2: 	Type : 1G M-C (Gig-Copper)
      Port 1/1/3: 	Type : 1G M-C (Gig-Copper)
      Port 1/1/4: 	Type : 1G M-C (Gig-Copper)
      Port 1/1/5: 	Type : 1G M-C (Gig-Copper)
      Port 1/1/6: 	Type : 1G M-C (Gig-Copper)
      Port 1/1/7: 	Type : 1G M-C (Gig-Copper)
      Port 1/1/8: 	Type : 1G M-C (Gig-Copper)
      Port 1/1/9: 	Type : 1G M-C (Gig-Copper)
      …
      Port 1/2/1: 	Type : 10GE SR 300m (SFP +)
      Port 1/2/2: 	Type : EMPTY
      Port 1/2/3: 	Type : 1G Twinax 1m (SFP)
      Port 1/2/4: 	Type : 1G Twinax 1m (SFP)
      
    2. Display information about the media device installed in a port.
      device(config)# show media ethernet 1/1/17
      
      Port 1/1/17: Type : 1GE M-SX(SFP)
      			Vendor: RUCKUS Networks. Version: A
      			Part# : 33210-100 Serial#: TAA11106M3GV
      
    3. Verify if your optics are official RUCKUS optics or another brand.
      device# show media validation ethernet 1/3/3
      
      Port       Supported   Vendor       Type                                                                            
      -------------------------------------------------------------
      1/3/3       Yes       RUCKUS       Type  : 10GE LR 10km (SFP+)  
      
  10. As a test, check the optical statistics for any enabled port.
    device(config)# show optic 2/1/1
    
     Port   Temperature     Tx Power      Rx Power       Tx Bias Current
    +-----+-------------+-------------+--------------+---------------------+
    2/1/1   32.2578 C    -002.5157 dBm  -002.8091 dBm    5.966 mA
            Normal       Normal         Normal           Normal 
    
  11. Verify the optic warning and alarm thresholds for any enabled port.
    device(config)# show optic thresholds 2/1/1