Configuring link dampening and alarms on ICX 7150 devices
Link dampening can help minimize outages due to microflaps. Microflaps can cause Layer
2 and Layer 3 reconvergence, resulting in outages lasting several minutes. When link
dampening is configured, microflaps can be monitored and ignored for a configured
period to prevent unnecessary outages. When link dampening and alarms are configured
with the
linkdampen command, you can monitor the link for flaps and determine when to bring the link
down.
All
RUCKUS ICX devices support the
linkdampen command, which enables link dampening with configurable sampling periods on a designated
port. Microflaps detected on the port and related changes in state are reported through
system logs and in
show interfaces ethernet command output so you can determine when a response is necessary.
Link dampening can be applied to any port,
including stacking and data ports. When the linkdampen command is applied to
a port in a LAG interface, the configuration is applied to all ports on the LAG.
To configure link dampening with alarms and the desired sampling period on a FastIron device, perform the following steps.
- Enter global configuration mode.
- Enter the
linkdampencommand as shown in the following example. After the keyword interval, enter a value from 1 through 4 to indicate the number of 250 millisecond segments to include in the sampling period. Include the port number on which link dampening is to be configured after the keyword ethernet.Note: The recommended sampling period is 1 second (interval value set to 4).device(config)# linkdampen interval 1 ethernet 1/1/1 ***CAUTION Link-Dampening may cause momentary traffic loss, may cause status convergence issues and other side effects. Use Link-Dampening only when required. Recommended usage Link-Dampening interval 4 - 1 second.
The example enables link dampening on Ethernet port 1/1/1 and sets the sampling interval to 1 (250 milliseconds).
- (Optional) To confirm the configuration, enter the
show running-configcommand.device(config)# show running-config Current configuration: ! ver 08.0.70cT213 ! stack unit 1 module 1 icx7150-48pf-poe-port-management-module module 2 icx7150-2-copper-port-2g-module module 3 icx7150-4-sfp-plus-port-40g-module stack-port 1/3/3 ! ! linkdampen interval 1 ethernet 1/1/1 <--- link dampening configuration for Ethernet port 1/1/1with a sampling interval of 250 milliseconds logging console ! !
- To check the link dampening configuration and any related microflaps or state changes
that have been recorded, enter the
show interfaces ethernetcommand followed by the port number as shown in the following example.device(config)# show interfaces ethernet 1/1/1 GigabitEthernet1/1/1 is up, line protocol is up Port up for 8 minute(s) 40 second(s) Hardware is GigabitEthernet, address is 609c.9ffe.03cc (bia 609c.9ffe.03cc) Configured speed auto, actual 1Gbit, configured duplex fdx, actual fdx Configured mdi mode AUTO, actual MDIX Member of L2 VLAN ID 1, port is untagged, port state is FORWARDING BPDU guard is Disabled, ROOT protect is Disabled, Designated protect is Disabled Link Error Dampening is Disabled STP configured to ON, priority is level0, mac-learning is enabled Openflow is Disabled, Openflow Hybrid mode is Disabled, Flow Control is config enabled, oper enabled, negotiation disabled Mirror disabled, Monitor disabled Mac-notification is disabled Link Micro Flap Dampening is enabled <--- Link dampening enabled on Ethernet port 1/1/1 Damping Interval:250 msecs Total Microflaps:0 <--- No microflaps during sampling period ! ! !
The following example configures link dampening for port 1/1/1. It sets the sampling
interval to a value of 1 (which represents one interval of 250 milliseconds). The
configuration is confirmed in output for the
show running-config command and detailed in output for the
show interface ethernet 1/1/1 command.
device# configure terminal device(config)# linkdampen interval 1 ethernet 1/1/1 ***CAUTION Link-Dampening may cause momentary traffic loss, may cause status convergence issues and other side effects. Use Link-Dampening only when required. Recommended usage Link-Dampening interval 4 - 1 second. device(config)# show running-config Current configuration: ! ver 08.0.70cT213 ! stack unit 1 module 1 icx7150-48pf-poe-port-management-module module 2 icx7150-2-copper-port-2g-module module 3 icx7150-4-sfp-plus-port-40g-module stack-port 1/3/3 ! ! linkdampen interval 1 ethernet 1/1/1 <--- link dampening configuration for Ethernet port 1/1/1with a sampling interval of 250 milliseconds logging console ! ! device(config)# show interfaces ethernet 1/1/1 GigabitEthernet1/1/1 is up, line protocol is up Port up for 8 minute(s) 40 second(s) Hardware is GigabitEthernet, address is 609c.9ffe.03cc (bia 609c.9ffe.03cc) Configured speed auto, actual 1Gbit, configured duplex fdx, actual fdx Configured mdi mode AUTO, actual MDIX Member of L2 VLAN ID 1, port is untagged, port state is FORWARDING BPDU guard is Disabled, ROOT protect is Disabled, Designated protect is Disabled Link Error Dampening is Disabled STP configured to ON, priority is level0, mac-learning is enabled Openflow is Disabled, Openflow Hybrid mode is Disabled, Flow Control is config enabled, oper enabled, negotiation disabled Mirror disabled, Monitor disabled Mac-notification is disabled Link Micro Flap Dampening is enabled <--- Link dampening enabled on Ethernet port 1/1/1 Damping Interval:250 msecs Total Microflaps:0 <--- No microflaps during sampling period Not member of any active trunks Not member of any configured trunks No port name IPG MII 0 bits-time, IPG GMII 0 bits-time MTU 1500 bytes, encapsulation ethernet MMU Mode is Store-and-forward 300 second input rate: 967999344 bits/sec, 202341 packets/sec, 99.85% utilization 300 second output rate: 967999352 bits/sec, 202341 packets/sec, 99.85% utilization 105261644 packets input, 62946463112 bytes, 0 no buffer Received 105261643 broadcasts, 0 multicasts, 0 unicasts 0 input errors, 0 CRC, 0 frame, 0 ignored 0 runts, 0 giants 105261789 packets output, 62946549822 bytes, 0 underruns Transmitted 105261788 broadcasts, 0 multicasts, 0 unicasts 0 output errors, 0 collisions Relay Agent Information option: Disabled Protected: No MAC Port Security: Disabled This port is not being monitored for queue drops Egress queues: Queue counters Queued packets Dropped Packets 0 105267070 1168968 1 0 0 2 0 0 3 0 0 4 0 0 5 23 0 6 0 0 7 0 0