Step 2: Configure the MCT VLAN, MCT Session VLAN, Recommended MCT Keep-Alive VLAN, and ICL Forwarding Delay
To create the recommended MCT keep-alive VLAN and MCT session VLAN for RUCKUS-1 and RUCKUS-2 devices in the topology of Basic MCT configuration, enter the following commands.
- Create an MCT keep-alive VLAN by
adding the tagged ports to the VLAN.
RUCKUS-1# configure terminal RUCKUS-1(config)# vlan 3001 name MCT-keep-alive RUCKUS-1(config-vlan-3001)# tagged ethernet 1/2/1 RUCKUS-1(config-vlan-3001)# exit
RUCKUS-2# configure terminal RUCKUS-2(config)# vlan 3001 name MCT-keep-alive RUCKUS-2(config-vlan-3001)# tagged ethernet 1/2/1 RUCKUS-2(config-vlan-3001)# exit
- Create a session VLAN by adding the ICL static LAG ID to the VLAN, and disable the spanning tree protocol.
- Create a router interface with session VLAN ID, and assign an IP address to the router interface.
- (Optional) Configure a delay in
seconds to wait after the ICL link comes up before regular traffic can be
transmitted. During the delay, only BPDU traffic is forwarded. The default is
0.
The valid range is 0 through 30.
RUCKUS-1(config)# cluster Building-A 200 <-creates cluster enters cluster config mode RUCKUS-1(config-cluster-Building-A)# icl-fwd-delay 3 RUCKUS-1(config-cluster-Building-A)# exit RUCKUS-1(config)#
RUCKUS-2(config)# cluster Building-A 200 RUCKUS-2(config-cluster-Building-A)# icl-fwd-delay 3 RUCKUS-2(config-cluster-Building-A)# exit RUCKUS-2(config)#
- (Optional) Configure a delay in
seconds to keep dynamic CCEP LAGs on a CCP peer in blocking state while CCP
comes up, for example, following a cluster-peer reload, ICL flap, or cluster
re-deployment or undeployment.
RUCKUS-1(config)# cluster Building-A 200 RUCKUS-1(config-cluster-Building-A)# ccep-up-delay 300 RUCKUS-1(config-cluster-Building-A)# exit RUCKUS-1(config)#
RUCKUS-2(config)# cluster Building-A 200 RUCKUS-2(config-cluster-Building-A)# ccep-up-delay 300 RUCKUS-2(config-cluster-Building-A)# exit RUCKUS-2(config)#
Note: The delay can be set to a value from 0 through 600 seconds. The recommended setting is 300. The default setting is 0, which disables the timer.
To implicitly configure the data VLAN as an MCT VLAN and add the ICL as a tagged member of the VLAN, enter the following commands.
RUCKUS-1(config)# vlan 10 name Data-VLAN-example RUCKUS-1(config-vlan-10)# tagged lag 2 lag 5 to 6
RUCKUS-2(config)# vlan 10 name Data-VLAN-example RUCKUS-2(config-vlan-10)# tagged lag 2 lag 5 to 6