MCT Board Type Compatibility
The RUCKUS ICX 7650 device and the RUCKUS ICX 7850 device can both run the same software versions although some of their capabilities are different. If these devices are used as MCT peers, some basic MCT functionality, such as the MAC table size, can be different between the peers. To avoid any issues, the device board type information is added in new fields as a TLV in the version information message used during the handshake signal, and this identifies the hardware. The board type check is performed before the Cluster Communication Protocol (CCP) is activated to prevent any unnecessary connection operations.
The show cluster command output
displays a message to explain when the CCP is down because the board type does not
match with
the peer device as shown in the following example.
Last Reason for CCP Down: Image version or board type doesn't match with peer Peer State: CCP Down (CCP is Down) Reason for CCP Down: Image version or board type doesn't match with peer