-
Long-Distance Stacking Ports
Last Updated
Sep 03, 2026
hardware. 1/3/1, 1/3/2 1/3/1, 1/3/2 ICX 7850-32Q 1/2/1 through 1/2/12, 1/3/1 through 1/3/8 1/3/1 through 1/3/8 ICX 7850-48C/48F/48FS 1/2/1 through 1/2/8 1/2/1 through 1/2/8 ICX models and 40-Gbps ports that can be used for long-distance data and stacking connections are listed in the following
-
Breakout
Last Updated
Sep 03, 2026
Breakout Breakout Breakout Feature Overview The Breakout feature allows certain 40-Gbps ports on ICX 7550 and ICX 7850 standalone units, as well as ICX 7850 stacking configurations, to be divided into four 10-Gbps subports using a breakout cable. Additionally, 100-Gbps ports can be divided into
-
show bfd
Last Updated
Sep 03, 2026
show bfd show bfd show bfd Displays Bidirectional Forwarding Detection (BFD) information. show bfd User EXEC mode This command is supported for Ruckus ICX 7750 and ICX 7850 devices. This command is supported for ICX 7850 devices only. The show bfd command displays the following information: Output
-
map vlan-range (VXLAN)
Last Updated
Sep 03, 2026
configuration mode The default VLAN cannot be mapped to a VNI. The maximum number of VLANs in a range is 256. This command is supported for router images only. This command is supported for RUCKUS ICX 7550, ICX 7650, and ICX 7850 devices only. For RUCKUS ICX 7650 and ICX 7850 devices, no more than
-
map vlan-range (VXLAN)
Last Updated
Sep 03, 2026
configuration mode The default VLAN cannot be mapped to a VNI. The maximum number of VLANs in a range is 256. This command is supported for router images only. This command is supported for RUCKUS ICX 7550, ICX 7650, and ICX 7850 devices only. For RUCKUS ICX 7650 and ICX 7850 devices, no more than
-
show bfd
Last Updated
Sep 03, 2026
show bfd show bfd show bfd Displays Bidirectional Forwarding Detection (BFD) information. show bfd User EXEC mode This command is supported for Ruckus ICX 7750 and ICX 7850 devices. This command is supported for ICX 7850 devices only. The show bfd command displays the following information: Output
-
Changing the Number of Load Sharing (ECMP) Paths for IPv4
Last Updated
Sep 03, 2026
of load-sharing paths supported by the Layer 3 device. You can change the maximum number of paths the Layer 3 device supports to a value from 2 through 8. On RUCKUS ICX 7650 and ICX 7850 devices, the value range for the maximum number of load-sharing paths is from 2 through 32. Maximum Number of
-
Configuration Considerations for uRPF
Last Updated
Sep 03, 2026
8100 and ICX 8200 devices. ICX 7850, ICX 7650, ICX 7550 Considerations Per-interface level configuration is available on VE interfaces and physical ports only. IPv4 and IPv6 unicast routed packets are subjected to uRPF check on ICX 7850 and ICX 7650 devices. Scaling numbers are reduced by half for
-
Changing the Number of Load Sharing (ECMP) Paths for IPv4
Last Updated
Sep 03, 2026
of load-sharing paths supported by the Layer 3 device. You can change the maximum number of paths the Layer 3 device supports to a value from 2 through 8. On RUCKUS ICX 7650 and ICX 7850 devices, the value range for the maximum number of load-sharing paths is from 2 through 32. Maximum Number of
-
Configuration Considerations for uRPF
Last Updated
Sep 03, 2026
packets, or OpenFlow is configured. Counters or logging information is unavailable for uRPF hits. After enabling reverse path check, you must reload the device for uRPF to be programmed. Tunnel over user VRF should not be configured on a device on which uRPF is enabled. ICX 7850, ICX 7650, ICX 7550