TCAM Space Configuration
Last Updated
Sep 03, 2026
forwarding-profile command in the RUCKUS FastIron Command Reference and the "Configuration Fundamentals" chapter in the RUCKUS FastIron Management Configuration Guide for more information. TCAM Space Allocation on ICX 7750 Devices Default Maximum Minimum IPv4 route entries 98304 131072 98304 IPv6 route
-
Configuring Delay Time for Notifying VE Down Event
Last Updated
Sep 03, 2026
Layer 2 loop detection protocols. Suppressing the link status notification allows a quick port status change and recovery to occur without triggering any of the changes that are necessary when a port stays down. By default, the delay time is not configured. Configuring delayed Layer 3 notifications on the VE feature is supported on ICX 7150, ICX 7250, ICX 7450, ICX 7550, ICX 7650, ICX 7750, and ICX 7850 product families from RUCKUS.
-
IPv6 PIM Convergence on MAC Address Movement
Last Updated
Sep 03, 2026
7250, ICX 7450, ICX 7550, ICX 7650, ICX 7750, and ICX 7850 devices. IPv6 PIM convergence on MAC address movement is applicable only when the multicast source and IPv6 PIM routers are in the same Layer 2 domain.
-
Enabling and Configuring the Control Bridge
Last Updated
Sep 03, 2026
as SPX connections have been identified. The following procedure describes CB configuration from an ICX stack. The same procedure can be performed from a standalone ICX 7650, ICX 7750, or ICX 7850. The only restriction is that the same port cannot be configured as a stacking port or trunk and as an
-
RUCKUS FastIron Stacking Configuration Guide, 08.0.95
Last Updated
Sep 03, 2026
contiguous ports. In FastIron 08.0.90 or later, you must observe the following rules to configure the stack-port or stack-trunk command related to the valid-stack-port set. The examples given apply to ICX 7750 devices. Valid-stack-port sets for different ICX models differ and are provided in the
-
Mirroring in a Campus Fabric Domain
Last Updated
Sep 03, 2026
Mirroring in a Campus Fabric Domain Mirroring in a Campus Fabric Domain Mirroring in a Campus Fabric Domain In a Campus Fabric domain, you can mirror ports in an ICX 7150 ICX 7150 PE unit, an ICX 7250 ICX 7250 PE unit, an ICX 7450 ICX 7450 PE unit, or an ICX 7650 ICX 7650, ICX 7750 ICX 7750, or ICX
-
show bfd
Last Updated
Sep 03, 2026
show bfd show bfd show bfd Displays Bidirectional Forwarding Detection (BFD) information. show bfd User EXEC mode This command is supported for Ruckus ICX 7750 and ICX 7850 devices. This command is supported for ICX 7850 devices only. The show bfd command displays the following information: Output
-
age
Last Updated
Sep 03, 2026
greater of the two values. If you set the age timer to 3 minutes for the port, and 10 minutes for the device, the port MAC address aging occurs in 10 minutes (the device-level setting), which is greater than the port setting that you have configured. On the ICX 7750, the port security age can only be
-
age
Last Updated
Sep 03, 2026
greater of the two values. If you set the age timer to 3 minutes for the port, and 10 minutes for the device, the port MAC address aging occurs in 10 minutes (the device-level setting), which is greater than the port setting that you have configured. On the ICX 7750, the port security age can only be
-
Metering
Last Updated
Sep 03, 2026
. Metering Capabilities Supported for Metering Features Feature On RUCKUS ICX devices Maximum meter available in the system 1024 Band types (bitmap) DROP Capabilities (bitmap) KBPS, BURST, STATS Maximum number of band per meter 1 or 2 2 is supported on the ICX 7750 Maximum color value 2