  • Supported Matrix and Unsupported Models

    RUCKUS SmartZone (LT-GD) Upgrade Guide, 6.1.2

    Last Updated Sep 03, 2026

    ZF7363 ZF7363-U ZF7441 ZF7761-CM ZF7762 ZF7762-AC ZF7762-S ZF7762-S-AC ZF7762-T ZF7962 Switch Management Feature Support Matrix Following are the supported ICX models: Supported ICX Models Supported ICX Models ICX 7150 ICX 7450 * ICX 7750 ICX 7250 ICX 7650 ICX 7850 ** ICX 7550 ICX 8200 * ICX 7750 is
  • Specifying a Single Source Interface for Specified Packet Types

    Last Updated Sep 03, 2026

    Specifying a Single Source Interface for Specified Packet Types Specifying a Single Source Interface for Specified Packet Types Specifying a Single Source Interface for Specified Packet Types This feature is supported on ICX 7150, ICX 7250, ICX 7450, ICX 7550, ICX 7650, and ICX 7850 switches. When
  • OSPF traps

    Last Updated Sep 03, 2026

    OSPF traps OSPF traps OSPF traps ICX 8100 and ICX 7150-ES devices do not support OSPF. You must configure the log adjacency command under the "router ospf" mode to see traps for the following objects: ospfIfStateChange trap, ospfNbrStateChange trap, ospfVirtIfStateChange trap, and
  • Supported ICX Models

    Last Updated Oct 23, 2026

    ICX 7150-ES devices. 08.0.80a 09.0.10a and subsequent patches 10.0.10f and subsequent patches ICX7150-C08P, -C08PT 08.0.92 09.0.10a and subsequent patches ICX7250 08.0.80a 09.0.10a and subsequent patches ICX7450 08.0.80a 09.0.10a and subsequent patches ICX7550 08.0.95a - ICX7550-4X25GF 10.0.10h
  • Quality of Service

    Last Updated Sep 03, 2026

    port can use as a portion of the total memory. Configuring a port to the egress queue drop counters Configuring a port to the egress queue drop counters The RUCKUS ICX 7150 has only one set of egress queue drop counters and can monitor only one port for the incrementing of the counters. By default, the device monitors the local CPU port for control packet drops. However, you can configure the device to monitor a different port for packet drops.
  • Quality of Service

    Last Updated Sep 03, 2026

    buffers that a port can use as a portion of the total memory. Configuring a port to the egress queue drop counters Configuring a port to the egress queue drop counters The RUCKUS ICX 7150 has only one set of egress queue drop counters and can monitor only one port for the incrementing of the counters
  • Selective Q-in-Q

    Last Updated Sep 03, 2026

    tunnels that can be configured per stack unit in a system. Maximum Selective VLAN Tunnels per Stacking Device ICX platform Maximum number of C-VLAN tunneling per stack unit ICX 7850 8000 ICX 7750 8000 ICX 7650 8000 ICX 7450 8000 ICX 7250 8000 ICX 7150 1024 For example, in a two-unit stack of ICX 7550
  • Specifying a Single Source Interface for Specified Packet Types

    Last Updated Sep 03, 2026

    Specifying a Single Source Interface for Specified Packet Types Specifying a Single Source Interface for Specified Packet Types Specifying a Single Source Interface for Specified Packet Types This feature is supported on ICX 7150, ICX 7250, ICX 7450, ICX 7550, ICX 7650, ICX 7750, and ICX 7850
  • IP Load Sharing

    Last Updated Sep 03, 2026

    Number of Paths Maximum Number of Paths ICX 7150 / ICX 7250 / ICX 7450 / ICX 7550 ICX 7650 / ICX 7750 / ICX 7850 Static IP route 4 8 32 OSPF 4 8 32 BGP4 1 4 32
  • Supported Matrix and Unsupported Models

    RUCKUS SmartZone (ST-GA) Upgrade Guide, 7.3.0

    Last Updated Oct 23, 2026

    ZF7982 ZF7781CM ZF7782 FZM300 ZF7782-E ZF7762-S ZF7372-E Switch Management Feature Support Matrix Following are the supported ICX models: Supported ICX Models Supported ICX Models ICX 7150 ICX 7450 * ICX 7750 ICX 7250 ICX 7650 ICX 7850 ** ICX 7550 ICX 8200 * ICX 7750 is supported through FastIron