⚠ This cached page may be outdated. Click refresh to get the latest content.
Cached Version You are Offline

You are viewing a cached version of this page.

You are currently offline. This page was loaded from cache.

Search Results: "icx 7850"

Showing 1,161 - 1,170 of 1,479 results

Relevance: best match to your search term first.

  • Stacking Terminology

    Last Updated Sep 03, 2026

    ports that must be used to configure stacking. There are two stacking directions, so each valid-stack-port set contains two ports. Each stack direction must start with a specific port in the valid-stack-port set. For example, an ICX 7850-48C, -48FS, or -48F device has the valid-stack-port set (x/2
  • Stacking Terminology

    Last Updated Sep 03, 2026

    ports that must be used to configure stacking. There are two stacking directions, so each valid-stack-port set contains two ports. Each stack direction must start with a specific port in the valid-stack-port set. For example, an ICX 7850-48C, -48FS, or -48F device has the valid-stack-port set (x/2/1
  • neighbor maximum-prefix

    Last Updated Sep 03, 2026

    configuration mode for BGP L2VPN EVPN configurations. This command can be configured in BGP L2VPN EVPN address family configuration mode for RUCKUS ICX 7850 and ICX 7550 devices only. For the BGP L2VPN EVPN address family, the default value is set to the supported EVPN route scale number, including all route
  • FastIron Licensed Features and Platform Support

    Last Updated Sep 03, 2026

    2x10gr 2x1G 2x1G, 2x10GR ICX 7550 L3 PREM MACSec l3-prem macsec l3-prem macsec l3-base l3-base, l3-prem, l3-base-macsec, l3-prem-macsec ICX 7650 L3 PREM MACSec l3-prem macsec l3-prem macsec l3-base l3-base, l3-prem, l3-base-macsec, l3-prem-macsec ICX 7850 L3 PREM MACsec l3-prem macsec l3-prem macsec
  • ACLs - Access Control Lists

    Last Updated Sep 03, 2026

    ACLs - Access Control Lists ACLs - Access Control Lists ACLs - Access Control Lists For considerations related to ACLs in an 802.1BR (SPX) configuration, refer to the Ruckus FastIron Campus Fabric Configuration Guide Feature ICX 7150 ICX 7250 ICX 7450 ICX 7550 ICX 7650 ICX 7750 ICX 7850 IPv4/IPv6
  • Image Verification in FIPS or CC Mode

    Last Updated Sep 03, 2026

    current software version of an ICX 7850 as version 08.0.95 and provides additional details on the image file and the modules installed in the device. Copyright (c) Ruckus Networks, Inc. All rights reserved. UNIT 1: compiled on Aug 13 2020 at 03:40:24 labeled as TNR08095 (63863960 bytes) from Primary
  • Common Criteria Overview

    Last Updated Sep 03, 2026

    FIPS- and Common Criteria-certified. MACsec is supported on ICX 7550, ICX 7650, and ICX 7850 devices. The following table summarizes support for Common Criteria protection profiles by FastIron device. Common Criteria protection profiles supported by device Platform NDcPP2.2e MACsec
  • ip route bfd

    Last Updated Sep 03, 2026

    recommended to use the default values. This command is supported for Ruckus ICX 7750 and ICX 7850 devices. The no form of the command removes the configured BFD session parameters. The following example configures a BFD session on an IP static route. The default BFD session timer values are applied. device
  • Campus Fabric (SPX) Image Upgrade

    Last Updated Sep 03, 2026

    image cannot be stored on an ICX 7650, ICX 7750, or ICX 7850 stack unit. To copy the image of a PE in a Campus Fabric domain, the auto image copy process accesses the correct PE image on a TFTP server. If the correct image is found on the server, it is downloaded to the mismatched unit. Once the
  • show ipv6 multicast mcache

    Last Updated Sep 03, 2026

    7750, ICX 7650, and ICX 7850 devices, l2mc is replaced with ipmc in the output. ref-cnt The number of mcaches using this IPMC. This example shows information in the multicast forwarding mcache: Device#show ipv6 multicast mcache Example: (S G) (MAC ADDR) cnt=: SRC and GRP IPv4/IPv6 address, Multicast