Configuring a Custom Port Number for Connection to SmartZone
By default, ICX switches use TCP destination port
22 to connect with SmartZone. Use the manager ssh-port command to
configure a different port number for connecting with SmartZone.
The following example configures an ICX
switch to connect to SmartZone over SSH port 25. A warning message is displayed as
shown
if a session is already established. You must confirm the configuration update when
prompted before the new connection is established. Check configuration status with
the
show manager
status
command.
device# configure terminal device(config)# manager ssh-port DECIMAL Enter a decimal value (Default 22) device(config)# manager ssh-port 25 device(config)# manager ssh-port 25 <-- Warning message --> Current session if established will be dropped to establish a new session with port 25. Are you sure? (enter 'y' or 'n'): y <-- You must confirm the configuration. ! ! device(config)# exit device# show manager status SYSLOG: <14> May 08 08:45:00 ICX CLI CMD: "show manager status" by super user from console ============ MGMT Agent State Info =================== Manager mode: SZ Config Status:Enabled Operation Status:Enabled State:SSH CONNECTED Prev State:SSH CONNECTING Event:SZ_SSH_CONNECT_EVENT BSICLOUD Status : Disabled SWR Host : sw-registrar.ruckuswireless.com SWR List : None SWR fqdn : None DNS List : None Active FQDN List : None Backup FQDN List : None Active List : 10.177.19.14 Backup List : None Active List IPV6 : 2001:df3:80d:826f::114 Backup List IPV6 : None DHCP Option 43 : No DHCP Opt 43 List : None DHCPV6 LIST : None Merged List : 10.177.19.14 2001:df3:80d:826f::114 SZ IP Used : 10.177.19.14 Port List : None Server Port Used : 443 Query Status : APPROVED SSH Tunnel Status -: Tunnel Status : Established SSH Port : 22 CLI IP/Port : 127.255.255.253/57316 SNMP IP/Port : 127.255.255.254/10825 Syslog IP/Port : 127.0.0.1/20514 HTTP CLIENT IP/Port : 127.255.255.252/36431 HTTP SERVER IP/Port : 127.0.0.1/5080