Summary:
DHCP configuration issue with RUCKUS
One.
Symptom:
RUCKUS
Edge cannot obtain an IP address when configured in
mixed mode with both internal and external DHCP.
Condition: - Turn on
the PIN and Sub-interface FF on RUCKUS One.
- Set up
two RUCKUS Edge devices (RE1 and RE2) with three
interfaces (WAN, LAN and Cluster) and onboard them to
RUCKUS One.
- After
completing the enrollment process and waiting for the
Need
port config status on the node.
Test case:
A PIN profile is
set up to use an external DHCP pool for the PIN UE (User
Equipment) and an internal DHCP pool is configured for WebAuth.
Due to this mixed configuration, the UE will not be able to
obtain an IP address. This happens because the system is trying
to manage two different DHCP pools (external for PIN UE and
internal for WebAuth), leading to a conflict that prevents the
UE from successfully receiving an IP address.
Allowed
configuration for a PIN profile: - Both
WebAuth and PIN-UE using internal DHCP
- Both
WebAuth and PIN-UE using external DHCP
Prohibited
configuration for a PIN profile: - WebAuth
using internal DHCP with PIN-UE using external DHCP
- WebAuth
using external DHCP and PIN-UE using internal DHCP
Workaround:
|