Last Updated
Aug 25, 2026
RUCKUS ICX Switches
Product Guides
Administer and Manage
guide supports the following Ruckus products: • Ruckus ICX 7850 Series • Ruckus ICX 7750 Series • Ruckus ICX 7650 Series • Ruckus ICX 7450 Series • Ruckus ICX 7250 Series • Ruckus ICX 7150 Series NOTE ICX 7150-C08PT devices do not support web management for FastIron release 08.0.92, with the exception
-
Last Updated
Aug 20, 2026
RUCKUS ICX Switches
Product Guides
Software License
Licensing rules for ICX 7450 and ICX 7250 devices.......................................................................................................................14 ICX 7750 Certificate of Entitlement
-
Flow table entries
Last Updated
Sep 03, 2026
Matching precedence of the entry Counters Statistics for matching packets Instructions Action set or pipeline processing Cookie Opaque data sent by the OpenFlow Controller RUCKUS ICX devices support the OpenFlow match fields in the following tables. OpenFlow match fields for ICX 7750 and ICX 7450 Match
-
RUCKUS FastIron Features and Standards Support Matrix, 09.0.10
Last Updated
Sep 03, 2026
-
sflow sample
Last Updated
Sep 03, 2026
that you do not change the denominator to a value lower than the default. Sampling requires CPU resources. Using a low denominator for the sampling rate can cause high CPU utilization. On RUCKUS ICX 7750, ICX 7450, ICX 7250, ICX 7650, ICX 7850, and ICX 7550 the CPU-bound sFlow sample packets are
-
sflow sample
Last Updated
Sep 03, 2026
that you do not change the denominator to a value lower than the default. Sampling requires CPU resources. Using a low denominator for the sampling rate can cause high CPU utilization. On RUCKUS ICX 7750, ICX 7450, ICX 7250, ICX 7650, ICX 7850, and ICX 7550 the CPU-bound sFlow sample packets are
-
Enabling DOM
Last Updated
Sep 03, 2026
-monitor Enable optical monitoring and set alarm/warn interval to default(8 minutes) The default alarm interval for the ICX 7450, ICX 7550, ICX 7650, and ICX 7850 is 8 minutes. The default alarm interval for the ICX 7250 and ICX 7150 is 3 minutes. Ports that are down are not included for optical
-
Configuration Notes for PVLANs and Standard VLANs
Last Updated
Sep 03, 2026
domain. PVLAN Support Matrix Platform Forwarding Type Tagged Port Untagged Port ISL Port Multiple Promiscuous Port ICX 7150 Hardware Yes Yes Yes Yes ICX 7250 Hardware Yes Yes Yes Yes ICX 7450 Hardware Yes Yes Yes Yes ICX 7650 Hardware Yes Yes Yes Yes ICX 7850 Hardware Yes Yes Yes Yes
-
LAG Formation Rules
Last Updated
Sep 03, 2026
enabled on an individual port within a LAG. sFlow cannot be configured on the LAG virtual interface. sFlow must be configured in LAG mode for each of the member ports separately. RUCKUS ICX 7450 devices do not support change in speed of a 2.5G paired port, if at least one of the ports is part of a LAG
-
Configuration Considerations for DHCP Servers
Last Updated
Sep 03, 2026
binding scalability for RUCKUS ICX devices for a stand-alone switch or a stack: Device IP DHCP binding scalability RUCKUS ICX 7150 500 RUCKUS ICX 7250 500 RUCKUS ICX 7450 500 RUCKUS ICX 7550 500 RUCKUS ICX 7650 500 RUCKUS ICX 7750 500 RUCKUS ICX 7850 500 DHCP address pools A DHCP address pool can be