IGMP Snooping Software Resource Limits
Last Updated
Sep 03, 2026
Maximum Maximum RUCKUS ICX 7150 3072 3072 8000 8000 RUCKUS ICX 7550 6144 (all Profiles) 6144 (all Profiles) RUCKUS ICX 7850 6144 (Profile 1, Profile 2 and Profile 4) 8192 (Profile3) 6144 (Profile 1, Profile 2 and Profile 4) 8192 (Profile3) RUCKUS ICX 8100 1000 (Profile 1 or Profile 2) 4096 (Profile 3
-
tunnel tos
Last Updated
Sep 03, 2026
. ICX 7150 devices do not support tunnels. The no form of the command removes the ToS configuration on the VTI. The following example shows how to configure a ToS value of 3 for an IPsec tunnel identified as 1. device(config)# interface tunnel 1 device(config-tnif-1)# tunnel mode ipsec ipv4 device(config-tnif-1)# tunnel tos 3 Release version Command history 08.0.41 This command was introduced.
-
Zero Touch Provisioning using Group level Configuration
Last Updated
Sep 22, 2026
define common configuration that is applicable to all the switch models in the group and another option to select configuration based on switch family, for example ICX 7150, ICX 7250, and so on. When a new switch without any existing configuration running FastIron version 8.0.90a or later version
-
qos egress-shape-ifg-bytes
Last Updated
Sep 03, 2026
and IFG bytes to be added to egress shaping in the range 1 through 127. Global configuration mode This command is supported on Ruckus ICX 7150, ICX 7250, ICX 7450,, ICX 7650, and ICX 7750 devices. For the ICX 7650, we recommend using a value greater than or equal to 20 bytes. The no form of the
-
tunnel path-mtu-discovery
Last Updated
Sep 03, 2026
Disables aging for PMTUD. Tunnel interface configuration mode ICX 7150 devices do not support tunnels. The no form of the command disables PMTUD and resets the aging to the default value of 10 minutes. The following example changes the reset time (default age timer) to a value of 25. device(config
-
tunnel protection ipsec profile
Last Updated
Sep 03, 2026
7450 devices. ICX 7150 devices do not support tunnels. The no form of the command removes the IPsec profile configuration. The following example shows how to configure an IPsec profile named prof_blue on a VTI with the tunnel ID 1 for an IPsec IPv4 tunnel. device# configure terminal device (config
-
tunnel tos
Last Updated
Sep 03, 2026
. ICX 7150 devices do not support tunnels. The no form of the command removes the ToS configuration on the VTI. The following example shows how to configure a ToS value of 3 for an IPsec tunnel identified as 1. device(config)# interface tunnel 1 device(config-tnif-1)# tunnel mode ipsec ipv4 device(config-tnif-1)# tunnel tos 3 Release version Command history 08.0.41 This command was introduced.
-
Stacking Deployment Introduction
Last Updated
Sep 03, 2026
trapped to the CPU. As a result, failure to enable STP in a stack may have significant impact on traffic in a production environment. STP is enabled by default in switch images. It is not enabled by default in router images. ICX 7150 and ICX 7250 devices must pre-load licenses to enable 10-Gbps stacking ports that allow a unit to join a stack. Refer to the Ruckus FastIron Software Licensing Guide for details on ICX licenses.
-
Specifying IPv6 SNMP Parameters
Last Updated
Sep 03, 2026
IPv6 host address. device# configure terminal device(config)# snmp-server host ipv6 2001:DB8:89::13 mypublic port 200 device(config)# write memory device(config)# snmp-client ipv6 2001:DB8:89::23 device(config)# snmp-server trap-source ethernet 1/2/1 device(config)# snmp-server enable traps holddown-time 40 The following RUCKUS ICX devices support IPv6 for SNMPv3: ICX 7150, ICX 7250, ICX 7450, ICX 7550, ICX 7650, ICX 7750, and ICX 7850
-
Enabling priority flow control for a single priority group
Last Updated
Sep 03, 2026
ICX 7750 devices. The ICX 7150, ICX 7650, ICX 7850, and ICX 7550 devices do not support PFC. Enter global configuration mode. device# configure terminal Enable PFC for PG 1. device(config)# priority-flow-control 1 There are four PGs numbered from 0 through 3. Return to privileged EXEC mode. device