-
system-max ip-static-arp
Last Updated
Sep 03, 2026
7250 512 2048 ICX 7450 512 6000 ICX 7550 512 6000 ICX 7650 512 1024 ICX 7750 512 1024 ICX 7850 512 1024 ICX 8100 512 2048 ICX 8200 512 2048 The no form of the command resets the number of allowable entries in the static ARP table to the default value. The following example increases the maximum
-
encryption-algorithm
Last Updated
Sep 03, 2026
supported for ESP encryption. IPsec proposal configuration mode Multiple encryption algorithms may be configured for an IPsec proposal. For an IPsec tunnel to come up successfully, IPsec peer devices must be configured with a common encryption algorithm. RUCKUS ICX 7450 supports dual mode for encryption
-
priority-flow-control enable
Last Updated
Sep 03, 2026
configuration mode This command is supported only on Ruckus ICX 7250, ICX 7450, and ICX 7850 devices. This command is supported for RUCKUS ICX 7550 and ICX 7850 devices only. To enable global PFC, symmetrical flow control (SFC) must be disabled. You must enable PFC globally before you configure it
-
Flow table entries
Last Updated
Sep 03, 2026
. The RUCKUS ICX 7650, ICX 7450, and ICX 7250 devices support enabling ports in either Layer 2, Layer 3, or Layer23 mode. OpenFlow Match Rules Match rule RUCKUS ICX device Port enabled for Layer 2 mode Yes Source port Yes Source or destination MAC address Yes These devices support either source MAC
-
encryption-algorithm
Last Updated
Sep 03, 2026
supported for ESP encryption. IPsec proposal configuration mode Multiple encryption algorithms may be configured for an IPsec proposal. For an IPsec tunnel to come up successfully, IPsec peer devices must be configured with a common encryption algorithm. RUCKUS ICX 7450 supports dual mode for encryption
-
link-config gig copper autoneg-control
Last Updated
Sep 03, 2026
autoneg-control 10m-auto ethernet 1/1/1 Release version Command history 08.0.20 This command was introduced for the Ruckus ICX 7450, but the downshift option was not supported. 08.0.30 This command was introduced for the Ruckus ICX 7250, but the downshift option was not supported. 08.0.40 The downshift option was removed.
-
link-config gig copper autoneg-control
Last Updated
Sep 03, 2026
autoneg-control 10m-auto ethernet 1/1/1 Release version Command history 08.0.20 This command was introduced for the Ruckus ICX 7450, but the downshift option was not supported. 08.0.30 This command was introduced for the Ruckus ICX 7250, but the downshift option was not supported. 08.0.40 The downshift option was removed.
-
priority-flow-control enable
Last Updated
Sep 03, 2026
configuration mode This command is supported only on Ruckus ICX 7250, ICX 7450, and ICX 7850 devices. This command is supported for RUCKUS ICX 7550 and ICX 7850 devices only. To enable global PFC, symmetrical flow control (SFC) must be disabled. You must enable PFC globally before you configure it
-
license delete unit
Last Updated
Sep 03, 2026
unit number and the index number to delete a license from a specific unit. Privileged EXEC level. Use the license delete perpetual command to delete an SAU license. On the ICX 7450 and ICX 7250 devices, if more than one non-node locked license file is installed, the deletion of the license file
-
system-max ip-static-arp
Last Updated
Sep 03, 2026
7250 512 2048 ICX 7450 512 6000 ICX 7550 512 6000 ICX 7650 512 1024 ICX 7750 512 1024 ICX 7850 512 1024 The no form of the command resets the number of allowable entries in the static ARP table to the default value. The following example increases the maximum number of static ARP table entries you