deny (Standard IPv4 ACLs)
Last Updated
Sep 03, 2026
example, appending /24 to an IPv4 address is equivalent to specifying 0.0.0.255 in the wildcard mask format. On RUCKUS ICX 7150 devices, ACL logging is not supported for egress ACLs. On RUCKUS ICX 7150 and ICX 7750 devices, ACL logging is not supported for egress ACLs. For the log keyword to trigger a log
-
TCP Keychain Options
Last Updated
Sep 03, 2026
. receive-id: Configures the identifier to be compared with the key identifier received in a TCP segment. Valid decimal values are 0 through 255. The no form of the command removes the identifier. TCP Keychain Considerations The keychain keychain-name tcp command is not supported on ICX 7150 devices. It
-
deny (Standard IPv4 ACLs)
Last Updated
Sep 03, 2026
example, appending /24 to an IPv4 address is equivalent to specifying 0.0.0.255 in the wildcard mask format. On RUCKUS ICX 7150 and ICX 7750 devices, ACL logging is not supported for egress ACLs. On RUCKUS ICX 7150 devices, ACL logging is not supported for egress ACLs. For the log keyword to trigger a log
-
User-configurable Scheduler Profile Configuration
Last Updated
Sep 03, 2026
buffer capacity, the ICX 7150, ICX 7150-ES, ICX 8100, and ICX 8200 switches may drop frames before they are properly scheduled. Under this condition, configure the egress buffer profile to support WRR or Mixed mode and increase the port-share level of the profile. If you create a profile specifying
-
RUCKUS One Online Help
Last Updated
Sep 22, 2026
FastIron 09.0.10f (router image). The ICX 7150-C08P/PT must be upgraded with a switch image. The following is a list of supported RUCKUS ICX switch models: ICX 7150 ICX 7550 ICX 7650 ICX 7850 ICX 8100 ICX 8200 For the list of supported ICX switches, refer to: https://www.ruckusnetworks.com/ruckus-one
-
Zero Touch Provisioning using Group level Configuration
Last Updated
Sep 03, 2026
define common configuration that is applicable to all the switch models in the group and another option to select configuration based on switch family, for example ICX 7150, ICX 7250, and so on. When a new switch without any existing configuration running FastIron version 8.0.90a or later version
-
Zero Touch Provisioning using Group level Configuration
Last Updated
Sep 03, 2026
define common configuration that is applicable to all the switch models in the group and another option to select configuration based on switch family, for example ICX 7150, ICX 7250, and so on. When a new switch without any existing configuration running FastIron version 8.0.90a or later version
-
Zero Touch Provisioning using Group level Configuration
Last Updated
Sep 03, 2026
define common configuration that is applicable to all the switch models in the group and another option to select configuration based on switch family, for example ICX 7150, ICX 7250, and so on. When a new switch without any existing configuration running FastIron version 8.0.90a or later version
-
qos egress-shape-ifg-bytes
Last Updated
Sep 03, 2026
and IFG bytes to be added to egress shaping in the range 1 through 127. Global configuration mode This command is supported on Ruckus ICX 7150, ICX 7250, ICX 7450,, ICX 7650, and ICX 7750 devices. This command is supported on ICX 7650, and ICX 8100 devices only. It is recommend to use a value
-
tunnel tos
Last Updated
Sep 03, 2026
. ICX 7150 devices do not support tunnels. The no form of the command removes the ToS configuration on the VTI. The following example shows how to configure a ToS value of 3 for an IPsec tunnel identified as 1. device(config)# interface tunnel 1 device(config-tnif-1)# tunnel mode ipsec ipv4 device(config-tnif-1)# tunnel tos 3 Release version Command history 08.0.41 This command was introduced.