-
Configuring sFlow
Last Updated
Sep 03, 2026
. ICX 8200 devices support sampling only at the global level. The sflow sample command cannot be applied at the interface or LAG level. device(config)# sflow sample 2048 device(config)# interface ethernet 1/1/1 device(config-if-1/1/1)# sflow sample 8192 device(config)# lag test static id 1 device
-
Configuring sFlow
Last Updated
Sep 03, 2026
. ICX 8200 devices support sampling only at the global level. The sflow sample command cannot be applied at the interface or LAG level. device(config)# sflow sample 2048 device(config)# interface ethernet 1/1/1 device(config-if-1/1/1)# sflow sample 8192 device(config)# lag test static id 1 device
-
show chassis
Last Updated
Sep 03, 2026
Warning level.......: 102.0 deg-C Shutdown level......: 105.0 deg-C Boot Prom MAC : 609c.9fe2.12ce The following is sample output from the show chassis command executed on an ICX 8200 device. ICX8200-48PF2 Router# show chassis The stack unit 1 chassis info: Power supply 1 (AC - PoE) present, status ok
-
Last Updated
Aug 25, 2026
RUCKUS ICX Switches
Product Guides
Administer and Manage
editorial updates Updated: Minor editorial updates were made throughout the Configuration Guide. Throughout the guide. TABLE 3 Key Features and Enhancements in FastIron 10.0.00 (December 15, 2022) Feature Description Reference RUCKUS ICX 8200 New: Added support for RUCKUS ICX 8200 devices. Throughout the
-
RUCKUS SmartZone (LT-GA) Upgrade Guide, 7.2.0
Last Updated
Sep 03, 2026
ZF7982 ZF7781CM ZF7782 FZM300 ZF7782-E ZF7762-S ZF7372-E Switch Management Feature Support Matrix Following are the supported ICX models: Supported ICX Models Supported ICX Models ICX 7150 ICX 7450 * ICX 7750 ICX 7250 ICX 7650 ICX 7850 ** ICX 7550 ICX 8200 * ICX 7750 is supported through FastIron
-
RUCKUS SmartZone (LT-GD) Upgrade Guide, 6.1.2
Last Updated
Sep 03, 2026
ZF7363 ZF7363-U ZF7441 ZF7761-CM ZF7762 ZF7762-AC ZF7762-S ZF7762-S-AC ZF7762-T ZF7962 Switch Management Feature Support Matrix Following are the supported ICX models: Supported ICX Models Supported ICX Models ICX 7150 ICX 7450 * ICX 7750 ICX 7250 ICX 7650 ICX 7850 ** ICX 7550 ICX 8200 * ICX 7750 is
-
Last Updated
Sep 03, 2026
RUCKUS ICX Switches
Product Guides
Administer and Manage, Configure and Deploy, Install and Upgrade
2 to 12 units configured in a ring or linear topology. The units in a stack are from the same model family; for example, a stack can be an ICX 8200 stack or an ICX 7850 stack, but it cannot combine ICX 8200 and ICX 7850 devices. Stack members can be physically separated or located together. For
-
Changing a Live Linear-topology Trunk to a Ring
Last Updated
Sep 03, 2026
example uses an ICX 8200 two-unit stack with a linear-topology trunk between ports 1/2/1 to 1/2/4 and 2/2/1 to 2/2/4. Complete the following steps to convert the linear-topology trunk to a ring-topology stack. Enter global configuration mode on the active controller. ICX8200-24P Router# configure
-
Changing a Live Linear-topology Trunk to a Ring
Last Updated
Sep 03, 2026
uses an ICX 8200 two-unit stack with a linear-topology trunk between ports 1/2/1 to 1/2/4 and 2/2/1 to 2/2/4. Complete the following steps to convert the linear-topology trunk to a stacking ring. Enter global configuration mode on the active controller. ICX8200-24P Router# configure terminal Enter
-
RUCKUS SmartZone (LT-GA) Upgrade Guide, 7.1.1
Last Updated
Sep 03, 2026
** ICX 7550 ICX 8200 * ICX 7750 is supported through FastIron 08.0.95 release. ** FastIron 08.0.95a or later is required for managing ICX7550 switches. ICX switches must be running FastIron 08.0.80a at a minimum to connect to SmartZone. An ICX switch running unsupported firmware can still connect to