FastIron Stacking Ports and Bandwidth
Last Updated
Sep 03, 2026
under uplink-100g configuration. ICX 7550-24F and ICX 7550-24ZP models support 1 X 100-Gbps data uplink. Device Stacking Port ICX 8100 C08PF/C16PF: 2X10Gbps stacking or uplink on Module-2 All others 24- or 48-port models: 4X10 Gbps stacking or uplink on Module-2 ICX 8200 C08PF: 2 X 10 Gbps stacking
-
DSCP-Based QoS Configuration
Last Updated
Sep 03, 2026
on the ingress port works on all traffic except GRE tunnels; classification on these remains based on Layer 2 (IEEE 802.1p) trust. For GRE tunnels, you can use ACLs to configure classification based on the DSCP value. On ICX 8100 and ICX 8200 devices, configuring both DSCP trust and Traffic Policy
-
Applying ACLs to Rate Limit Inbound CPU Traffic
Last Updated
Sep 03, 2026
filter or rate limit specific incoming traffic. For example, you can create ACLs to perform any of the following actions: Rate limit DHCP packets sent to the CPU Permit ICMP packets Permit packets from a known subnet Deny Telnet and SSH connections On ICX 8100 and ICX 8200 devices, configuring both
-
Encapsulated Remote Switched Port Analyzer
Last Updated
Sep 03, 2026
tunnel cannot be terminated on the switch. Support is added for ICX 8200 devices in FastIron 10.0.10h_cd1. Speed mismatches between the source and destination interfaces can cause packet drops or incomplete mirroring. ERSPAN has not been validated with third-party implementations; interoperability may
-
Flexible Authentication (802.1x Authentication and MAC Authentication)
Last Updated
Sep 03, 2026
Flexible Authentication (802.1x Authentication and MAC Authentication) Flexible Authentication (802.1x Authentication and MAC Authentication) Flexible Authentication (802.1x Authentication and MAC Authentication) Feature ICX 7550 ICX 7650 ICX 7850 ICX 8100 ICX 8200 IEEE 802.1x Authentication
-
Configuring Port Settings for a Switch
Last Updated
Sep 03, 2026
controller. RUCKUS ICX devices must be running FastIron firmware version 10.0.20c or later. SmartZone must be running version 7.1.1 or later. RUCKUS ICX models supported: ICX 8200. Neighbhor Discover Inspection (IPv6): Click the toggle button to enable ( ON) the Neighbhor Discover Inspection (IPv6
-
Selective Q-in-Q
Last Updated
Sep 03, 2026
SVLAN domain, that is, to all the member ports of the SVLAN might cause traffic leak between CVLANs. PVLAN is not supported on selective Q-in-Q enabled ports. Selective Q-in-Q cannot be configured on dot1x enabled ports and vice versa. For ICX 8100 and ICX 8200 devices, when the Q-in-Q tunnel is
-
Selective Q-in-Q
Last Updated
Sep 03, 2026
SVLAN domain, that is, to all the member ports of the SVLAN might cause traffic leak between CVLANs. PVLAN is not supported on selective Q-in-Q enabled ports. Selective Q-in-Q cannot be configured on dot1x enabled ports and vice versa. For ICX 8200 devices, when the Q-in-Q tunnel is configured with
-
qos priority-to-pg
Last Updated
Sep 03, 2026
. Global configuration mode This command is not supported on Ruckus ICX 7150 or ICX 7650 devices. This command is not supported for RUCKUS ICX 8200, ICX 7150, or ICX 7650 devices. You must configure the priority-flow-control enable command to enable PFC globally before you configure priority-to-PG
-
sflow sample
Last Updated
Sep 03, 2026
power of 2. Refer to the Usage Guidelines section for information on the range of supported values. Global configuration mode Interface configuration mode LAG configuration mode For RUCKUS ICX 8200 and ICX 8100 devices, the command is supported in global configuration mode only. The value range for