  • Port-based fixed rate limiting configuration notes

    Last Updated Sep 03, 2026

    types of LAG. You can configure rate limiting on individual ports of the LAG. You cannot configure rate limiting on the LAG itself. The RUCKUS ICX 7650 applies rating limiting starting with the Layer 1 overhead. All other ICX devices begin counting the packet size from the Layer 2 header onwards.
  • ip tcp analytics rate

    Last Updated Sep 03, 2026

    normal traffic to the switch. ip tcp analytics rate threshold-rate no ip tcp analytics rate threshold-rate The default threshold rate is 1000 packets per second. This command is supported on ICX 7550, ICX 7650 and ICX 7850 devices only. threshold-rate The threshold rate at which an alarm or
  • ip tcp analytics rate

    Last Updated Sep 03, 2026

    normal traffic to the switch. ip tcp analytics rate threshold-rate no ip tcp analytics rate threshold-rate The default threshold rate is 1000 packets per second. This command is supported on ICX 7550, ICX 7650 and ICX 7850 devices only. threshold-rate The threshold rate at which an alarm or
  • system-max ip-vrf

    Last Updated Sep 03, 2026

    Configures the number of VRF instances supported. Refer to the Usage Guidelines section. Global configuration mode The range of maximum and minimum configurable VRF instance and the default values depends on the platform. Platform Minimum Default Maximum ICX 7250 4 16 16 ICX 7450 4 16 16 ICX 7650 16
  • Specifying IPv6 SNMP Parameters

    Last Updated Sep 03, 2026

    IPv6 host address. device# configure terminal device(config)# snmp-server host ipv6 2001:DB8:89::13 mypublic port 200 device(config)# write memory device(config)# management source-interface ethernet 1/2/1 protocol snmp device(config)# snmp-server enable traps holddown-time 40 The following RUCKUS ICX devices support IPv6 for SNMPv3: ICX 7550, ICX 7650, and ICX 7850.
  • OpenFlow Scaling

    Last Updated Sep 03, 2026

    OpenFlow Scaling OpenFlow Scaling OpenFlow Scaling ICX 7150 ICX 7650 ICX 7850 ICX 8200 Total number of flows per system 12,288 ~12,000 12,288 12,288 Total number of flows in Layer 2 mode per unit 74 512 1,472 200 Total number of flows in Layer 3 mode per unit IPv4: 73 IPv6: 256 IPv4: 1,536 IPv6
  • BGP4 Scaling

    Last Updated Sep 03, 2026

    BGP4 Scaling BGP4 Scaling BGP4 Scaling ICX 7150 ICX 7150-ES ICX 7550 ICX 7650 ICX 7850 ICX 8100 ICX 8200 VRF Instances with BGP4 Configured N/A N/A 32 64 64 N/A N/A BGP4 Routes (Unique. Under default VRF) N/A N/A As per forwarding profile configs ~128,000 As per forwarding profile configs N/A N/A
  • BGP4+ Scaling

    Last Updated Sep 03, 2026

    BGP4+ Scaling BGP4+ Scaling BGP4+ Scaling ICX 7150 ICX 7150-ES ICX 7550 ICX 7650 ICX 7850 ICX 8100 ICX 8200 VRF Instances with BGP4 Configured N/A N/A 32 64 64 N/A N/A BGP4+ Routes (Unique Under default VRF) N/A N/A As per forwarding profile configs ~7,000 As per forwarding profile configs N/A N/A
  • Security Scaling

    Last Updated Sep 03, 2026

    Security Scaling Security Scaling Security Scaling ICX 7150 ICX 7150-ES ICX 7550 ICX 7650 ICX 7850 ICX 8100 ICX 8200 Dot1x sessions [per port] Single Untagged auth-mode: 32 Multiple Untagged auth-mode: 8 32 32 32 32 Single Untagged auth-mode: 32 Multiple Untagged auth-mode: 8 Single Untagged auth
  • Campus Fabric Licensing

    Last Updated Sep 03, 2026

    Campus Fabric Licensing Campus Fabric Licensing Campus Fabric Licensing In a Campus Fabric network, devices configured as port extender (PE) units require the PoD license. In Campus Fabric (802.1BR or SPX), the ICX 7650 can be configured as the 802.1BR control bridge, and the ICX 7150, ICX 7450