-
Stacking fan table
Last Updated
Sep 03, 2026
Stacking fan table Stacking fan table Stacking fan table The following table shows the fan status for devices that support the stacking functionality. ICX 7150-ES and ICX 8100 models do not support stacking. Name, OID, and syntax Access Description snChasFan2Table 1.3.6.1.4.1.1991.1.1.1.3.2 None A
-
Clearing GRE statistics
Last Updated
Sep 03, 2026
a tunnel Interface back to the configured value, enter a command such as the following. device(config)#clear ip tunnel pmtud 3 Use the clear statistics tunnel command to clear GRE tunnel statistics for a specific tunnel ID number. To clear GRE tunnel statistics for tunnel ID 3, enter a command such as the following. device(config)# clear statistics tunnel 3 ICX 7150 devices do not support tunnels.
-
Unicast Reverse Path Forwarding Feasibility
Last Updated
Sep 03, 2026
Unicast Reverse Path Forwarding Feasibility Unicast Reverse Path Forwarding Feasibility Unicast Reverse Path Forwarding Feasibility The following table provides support information about uRPF. uRPF Feasibility uRPF is not supported on ICX 7150 devices. Device Configurable Mode ECMP Route Supported
-
IGMP Snooping Software Resource Limits
Last Updated
Sep 03, 2026
Maximum RUCKUS ICX 7150 1024 3072 512 3072 RUCKUS ICX 7250 512 8192 512 8192 RUCKUS ICX 7450 512 8192 512 8192 RUCKUS ICX 7550 512 8192 512 8192 RUCKUS ICX 7850 8192 8192 6144 6144 For ICX 7850 and ICX 7550 devices, values are used from the forwarding profile. Refer to the forwarding-profile command
-
Clearing GRE statistics
Last Updated
Sep 03, 2026
a tunnel Interface back to the configured value, enter a command such as the following. device(config)#clear ip tunnel pmtud 3 Use the clear statistics tunnel command to clear GRE tunnel statistics for a specific tunnel ID number. To clear GRE tunnel statistics for tunnel ID 3, enter a command such as the following. device(config)# clear statistics tunnel 3 ICX 7150 devices do not support tunnels.
-
Last Updated
Sep 02, 2026
Replacing a Fiber-Optic Transceiver Long-Reach Multimode Adapter Module Long-Reach Multimode Adapter Module RUCKUS ICX 7150, ICX 7250, and ICX 7750 Ethernet switches require a Long-Reach Multimode (LRM) adapter module to support LRM optics connections.
-
optical-monitor
Last Updated
Sep 03, 2026
timer for ICX 7250 and ICX 7150 devices is 3 minutes. Specifies the interval at which alarms and warning messages are sent. The default and minimum timer for ICX 7550, ICX 7650, and ICX 7850 devices is 8 minutes. The default timer for ICX 7150 devices is 3 minutes. Global configuration mode Interface
-
Manageability Feature Scaling
Last Updated
Sep 03, 2026
Manageability Feature Scaling Manageability Feature Scaling Manageability Feature Scaling Feature ICX 7150 ICX 7150-ES ICX 7550 ICX 7650 ICX 7850 ICX 8100 ICX 8200 Number of TACACS Servers 8 8 8 8 8 8 8 Number of RADIUS Servers 8 8 8 8 8 8 8 Number of SSH inbound/outbound sessions 5 - Inbound
-
optical-monitor
Last Updated
Sep 03, 2026
timer for ICX 7250 and ICX 7150 devices is 3 minutes. Specifies the interval at which alarms and warning messages are sent. The default and minimum timer for ICX 7450, ICX 7550, ICX 7650, and ICX 7850 devices is 8 minutes. The default timer for ICX 7250 and ICX 7150 devices is 3 minutes. Global
-
BGP4 - IPV4 Border Gateway Protocol
Last Updated
Sep 03, 2026
BGP4 - IPV4 Border Gateway Protocol BGP4 - IPV4 Border Gateway Protocol BGP4 - IPV4 Border Gateway Protocol Feature ICX 7150 ICX 7150-ES ICX 7550 ICX 7650 ICX 7850 ICX 8100 ICX 8200 BGP4 No No 08.0.95 08.0.70 08.0.90 No No BGP4 Graceful Restart No No 08.0.95 08.0.70 08.0.90 No No BGP4 Graceful