Configuring Symmetrical Flow Control
Last Updated
Sep 03, 2026
)# symmetrical-flow-control enable Enables SFC on priorities from 0 through 4. Enabling SFC using the symmetrical-flow-control enable command is recommended. For ICX 8200 devices, the all-priorities keyword is not supported. device(config)# symmetrical-flow-control enable all-priorities Enabling SFC on
-
OSPFv2 and OSPFv3 Scaling
Last Updated
Sep 03, 2026
OSPFv2 and OSPFv3 Scaling OSPFv2 and OSPFv3 Scaling OSPFv2 and OSPFv3 Scaling ICX 7150 ICX 7150-ES ICX 7550 ICX 7650 ICX 7850 ICX 8100 ICX 8200 VRF Instances with OSPFv2 Configured N/A N/A 32 50 50 N/A 16 OSPFv2 areas (Per-VRF-Instance) N/A N/A 64 8 64 N/A 64 OSPFv2 areas (Shared by all VRFs) 4 N/A
-
LLDP - Link Layer Discovery Protocol
Last Updated
Sep 03, 2026
LLDP - Link Layer Discovery Protocol LLDP - Link Layer Discovery Protocol LLDP - Link Layer Discovery Protocol Feature ICX 7150 ICX 7150-ES ICX 7550 ICX 7650 ICX 7850 ICX 8100 ICX 8200 LLDP 08.0.60 10.0.10d 08.0.95 08.0.70 08.0.90 10.0.10f 10.0.00 LLDP-MED 08.0.60 10.0.10d 08.0.95 08.0.70 08.0.90
-
Multi-VRF
Last Updated
Sep 03, 2026
Multi-VRF Multi-VRF Multi-VRF Feature ICX 7150 ICX 7150-ES ICX 7550 ICX 7650 ICX 7850 ICX 8100 ICX 8200 Multi-VRF IPv4 forwarding No No 08.0.95 08.0.70 08.0.90 No 10.0.00 Multi-VRF IPv6 forwarding No No 08.0.95 08.0.70 08.0.90 No 10.0.00 Multi-VRF for IPv4 and IPv6 unicast- static routing No No
-
xSTP - Spanning Tree Protocols
Last Updated
Sep 03, 2026
xSTP - Spanning Tree Protocols xSTP - Spanning Tree Protocols xSTP - Spanning Tree Protocols Feature ICX 7150 ICX 7150-ES ICX 7550 ICX 7650 ICX 7850 ICX 8100 ICX 8200 802.1s Multiple Spanning Tree 08.0.60 10.0.10d 08.0.95 08.0.70 08.0.90 10.0.10f 10.0.00 802.1s Multiple Spanning Tree enhancement
-
Selective QinQ
Last Updated
Sep 03, 2026
devices must be running FastIron firmware version 10.0.20b_cd2 or later SmartZone must be running version 7.1.1 or later RUCKUS ICX models supported: ICX 7550, ICX 7650, ICX 7850, and ICX 8200 New CVLAN only supports the model ICX 8200 Considerations Consider the following when configuring and using this
-
Selective QinQ
Last Updated
Sep 03, 2026
devices must be running FastIron firmware version 10.0.20b_cd2 or later SmartZone must be running version 7.1.1 or later RUCKUS ICX models supported: ICX 7550, ICX 7650, ICX 7850, and ICX 8200 New CVLAN only supports the model ICX 8200 Considerations Consider the following when configuring and using this
-
Supported Software and Hardware
Last Updated
Sep 03, 2026
Software Version Supported ICX 7550, ICX 7650, ICX 7850, ICX 8100, ICX 8200 FastIron 10.0.20 and subsequent release versions in the 10.0.2x code stream ICX 7150, ICX 7550, ICX 7650, ICX 7850, ICX 8100,ICX 8200 FastIron 10.0.10 and subsequent release versions in the 10.0.1x code stream ICX 7150, ICX
-
Locating a Device Using Port LEDs
Last Updated
Sep 03, 2026
, and ICX 8200 devices. The following example shows how to turn on port LEDs on a standalone unit or stack unit. device# led on The following example shows how to turn on port LEDs to locate a unit in a stack from the active unit. device# led on unit 5 Blink LED The led blink command sets all the
-
Rate Shaping Configuration Notes
Last Updated
Sep 03, 2026
multiples of minimum values supported on the platform. The following table shows the minimum and maximum values for output rate shaping on various devices. Values are in kilobits per second (Kbps) for all the platforms. Output Rate Shaping on ICX Devices Device Module Minimum Maximum ICX 8200 10 Gbps ports