clear dot1x statistics
Last Updated
Sep 03, 2026
statistics on a specific interface. device# configure terminal device(config)# clear dot1x statistics ethernet 1/1/1 Release version Command history 08.0.20 The all option was removed from the command for ICX 6430, ICX 6450, ICX 6610, and FCX devices. 08.0.40 The all option was removed from the command for ICX 7450, ICX 7750, and ICX 7250 devices. 08.0.70 The stack-unit option was added.
-
system-max ip-vrf
Last Updated
Sep 03, 2026
Configures the number of VRF instances supported. Refer to the Usage Guidelines section. Global configuration mode The range of maximum and minimum configurable VRF instance and the default values depends on the platform. Platform Minimum Default Maximum ICX 7250 4 16 16 ICX 7450 4 16 16 ICX 7650
-
IP Addressing
Last Updated
Sep 03, 2026
IP Addressing IP Addressing IP Addressing Feature ICX 7150 ICX 7250 ICX 7450 ICX 7550 ICX 7650 ICX 7850 Bandwidth for IP interfaces 08.0.61 08.0.30 08.0.30 08.0.95 08.0.70 08.0.90 Equal Cost Multi-Path (ECMP) load sharing 08.0.61 08.0.30 08.0.20 08.0.95 08.0.70 08.0.90 Virtual Interfaces 08.0.61
-
IPv6 Multicast Routing
Last Updated
Sep 03, 2026
IPv6 Multicast Routing IPv6 Multicast Routing IPv6 Multicast Routing Feature ICX 7150 ICX 7250 ICX 7450 ICX 7550 ICX 7650 ICX 7850 IPv6 multicast boundaries 08.0.61 08.0.40 08.0.20 08.0.95 08.0.70 08.0.90 Embedded RPv6 08.0.61 08.0.40 08.0.20 08.0.95 08.0.70 08.0.90 Multi-VRF support No 08.0.50
-
tunnel mode ipsec
Last Updated
Sep 03, 2026
packets transmitted over the tunnel. ipv6 Specifies the application of IPsec protection for IPv6 packets transmitted over the tunnel. Tunnel interface configuration mode IPsec is supported only on ICX 7450 devices. The no form of the command removes the IPsec mode configuration for the VTI. The
-
FastIron Devices and Campus Fabric Communication
Last Updated
Sep 03, 2026
FastIron Devices and Campus Fabric Communication FastIron Devices and Campus Fabric Communication FastIron Devices and Campus Fabric Communication An ICX 7650, ICX 7750, or ICX 7850 stack or standalone serves as the control bridge (CB) for attached ICX 7450, ICX 7250, or ICX 7150 devices configured
-
system-max ip-vrf
Last Updated
Sep 03, 2026
Configures the number of VRF instances supported. Refer to the Usage Guidelines section. Global configuration mode The range of maximum and minimum configurable VRF instance and the default values depends on the platform. Platform Minimum Default Maximum ICX 7250 4 16 16 ICX 7450 4 16 16 ICX 7650
-
RUCKUS ICX Switch Port Extender Deployment Guide
Last Updated
Sep 02, 2026
: Migrating an Existing Stack to Campus Fabric Deployment Scenario 4: Replacing a PE Deployment Scenario 5: Preventing an ICX 7250 or ICX 7450 from Being Discovered by Zero-Touch Deployment Scenario 6: Changing PE IDs Using SPX Interactive-Setup Deployment Scenario 7: SPX PE Movement: Moving PEs
-
ip multicast optimization
Last Updated
Sep 03, 2026
on ICX 7750 devices, and enabled by default on ICX 7450 and ICX 7250 devices. IPMC entry optimization is enabled by default. oif-list Shares the Output Interface Lists across entries. all Specifies all types of Output Interface Lists. Global configuration mode The no form of the command disables
-
logging enable ikev2
Last Updated
Sep 03, 2026
supported on the Ruckus ICX 7450, with an FPGA-based add-on crypto card. The following example configures syslog generation for IKEv2 events. device# configure terminal device(config)# logging enable ikev2 The following example configures logging of additional IKEv2 events. device# configure terminal