Loading the Flash Code Using TFTP
Last Updated
Sep 03, 2026
Loading the Flash Code Using TFTP Loading the Flash Code Using TFTP Loading the Flash Code Using TFTP For ICX7550 or ICX 7650 (running FastIron 08.0.80a and later) or ICX 7850, proceed to step 2. Copy the 08.0.80f non-UFI from the TFTP server into flash memory using the copy tftp flash command
-
Configuring sFlow
Last Updated
Sep 03, 2026
, meaning that, on average, one out of every N packets is sampled. The sflow sample command in global configuration mode or port mode specifies N, the denominator of the fraction. The sampling rate must be set depending on the input traffic rate. On RUCKUS ICX 7250, ICX 7450, ICX 7550, ICX 7650, and ICX
-
Transparent Clock
Last Updated
Sep 03, 2026
- Timestamp Point MII - MAC Interface The following topology shows the use case of PTP-TC using the ICX devices supporting PTP. Network Topology with Transparent Clock Using ICX 7850 Units PTP packet prioritization and the end-to-end transparent clock is supported by the RUCKUS devices listed in the
-
BGP EVPN Multihoming Overview
Last Updated
Sep 03, 2026
to as a leaf. VXLAN: Virtual eXtensible Local Area Network For more information on VXLAN-related terminology, refer to the VXLAN chapter. For more information on general BGP EVPN terminology, refer to BGP EVPN VXLAN. Requirements BGP EVPN Multihoming is supported for RUCKUS ICX 7850 and ICX 7550
-
BGP EVPN Multihoming Overview
Last Updated
Sep 03, 2026
to as a leaf. VXLAN: Virtual eXtensible Local Area Network For more information on VXLAN-related terminology, refer to the VXLAN chapter. For more information on general BGP EVPN terminology, refer to BGP EVPN VXLAN. Requirements BGP EVPN Multihoming is supported for RUCKUS ICX 7850 and ICX 7550
-
show cluster
Last Updated
Sep 03, 2026
type mismatch. The updated text is highlighted in bold. This example is only applicable to the Ruckus ICX 7850 platform running a FastIron 08.0.90 image. device> show cluster Cluster MgM 3000 ============= Rbridge Id: 3, Session Vlan: 3000, Keep-Alive Vlan: 3001 Cluster State: Deploy Client
-
Transparent Clock
Last Updated
Sep 03, 2026
- Timestamp Point MII - MAC Interface The following topology shows the use case of PTP-TC using the ICX devices supporting PTP. Network Topology with Transparent Clock Using ICX 7850 Units PTP packet prioritization and end-to-end transparent clock is supported by the following RUCKUS devices in both
-
Configuring sFlow
Last Updated
Sep 03, 2026
, and ICX 7850 devices, the CPU-bound sFlow sample packets are rate-limited to 50 samples per second to avoid high CPU utilization. You can change a module sampling rate only by changing the sampling rate of a port on that module. You can configure an individual port or a static LAG or a dynamic LAG
-
Image download using USB
Last Updated
Sep 03, 2026
correct image stored in the USB is used for port extender. If the USB does not have the correct image, the port extender will remain in a mismatched state. The USB status mode LED indicates the status of boot from USB and is present only for ICX 7650 and ICX 7850. Refer to the RUCKUS Hardware Installation Guide for more information.
-
graceful-restart (BGP)
Last Updated
Sep 03, 2026
the clear ip bgp neighbor command with the all parameter for the changes to the graceful restart parameters to take effect immediately. This command can be configured in BGP L2VPN EVPN address family configuration mode for RUCKUS ICX 7850 and ICX 7550 devices only. The no form of the command