DSCP-Based QoS Configuration
Last Updated
Sep 03, 2026
VE interfaces and GRE tunnel interfaces on ICX 7850, ICX 7650, and ICX 7550 devices. On ICX 8100 and ICX 8200 devices, configuring both DSCP trust and Traffic Policy is not recommended. When DSCP trust and Traffic Policy are configured on the same interface, trust DSCP will not be honored on Layer 3
-
Configuration Notes for PVLANs and Standard VLANs
Last Updated
Sep 03, 2026
domain. PVLAN Support Matrix Platform Forwarding Type Tagged Port Untagged Port ISL Port Multiple Promiscuous Port ICX 7150 Hardware Yes Yes Yes Yes ICX 7250 Hardware Yes Yes Yes Yes ICX 7450 Hardware Yes Yes Yes Yes ICX 7650 Hardware Yes Yes Yes Yes ICX 7850 Hardware Yes Yes Yes Yes
-
Configuration Notes for PVLANs and Standard VLANs
Last Updated
Sep 03, 2026
domain. PVLAN Support Matrix Platform Forwarding Type Tagged Port Untagged Port ISL Port Multiple Promiscuous Port ICX 7150-ES Hardware Yes Yes Yes Yes ICX 7150 Hardware Yes Yes Yes Yes ICX 7550 Hardware Yes Yes Yes Yes ICX 7650 Hardware Yes Yes Yes Yes ICX 7850 Hardware Yes Yes Yes Yes ICX 8100 Hardware Yes Yes Yes Yes ICX 8200 Hardware Yes Yes Yes Yes
-
Configuration Notes for PVLANs and Standard VLANs
Last Updated
Sep 03, 2026
private VLAN domain. PVLAN Support Matrix Platform Forwarding Type Tagged Port Untagged Port ISL Port Multiple Promiscuous Port ICX 7550 Hardware Yes Yes Yes Yes ICX 7650 Hardware Yes Yes Yes Yes ICX 7850 Hardware Yes Yes Yes Yes ICX 8100 Hardware Yes Yes Yes Yes ICX 8200 Hardware Yes Yes Yes Yes
-
sflow sample
Last Updated
Sep 03, 2026
that you do not change the denominator to a value lower than the default. Sampling requires CPU resources. Using a low denominator for the sampling rate can cause high CPU utilization. On RUCKUS ICX 7750, ICX 7450, ICX 7250, ICX 7650, ICX 7850, and ICX 7550 the CPU-bound sFlow sample packets are
-
ip ospf bfd
Last Updated
Sep 03, 2026
interfaces. If BFD is disabled on an interface using the ip ospf bfd disable command, and BFD is configured globally for OSPFv2, the BFD session will not come up on all the specified OSPFv2-enabled interface where it has been disabled. This command is supported for Ruckus ICX 7750 and ICX 7850 devices
-
Configuration Considerations for DHCP Servers
Last Updated
Sep 03, 2026
binding scalability for RUCKUS ICX devices for a stand-alone switch or a stack: Device IP DHCP binding scalability RUCKUS ICX 7150 500 RUCKUS ICX 7250 500 RUCKUS ICX 7450 500 RUCKUS ICX 7550 500 RUCKUS ICX 7650 500 RUCKUS ICX 7750 500 RUCKUS ICX 7850 500 DHCP address pools A DHCP address pool can be
-
BFD Considerations and Limitations
Last Updated
Sep 03, 2026
sessions to come up. For multi-unit LAGs, it is recommended to use Micro-BFD. Multi-hop BFD is not supported if micro-BFD is enabled. BFD is supported for ICX 7750 and ICX 7850 platforms. In a stack setup, a BFD session is programmed on the unit where the tx-port is present. Incoming BFD packets must be
-
Enabling DOM
Last Updated
Sep 03, 2026
-monitor Enable optical monitoring and set alarm/warn interval to default(8 minutes) The default alarm interval for the ICX 7450, ICX 7550, ICX 7650, and ICX 7850 is 8 minutes. The default alarm interval for the ICX 7250 and ICX 7150 is 3 minutes. Ports that are down are not included for optical
-
Configuration Fundamentals
Last Updated
Sep 03, 2026
filters Monitoring MAC address movement Overview of Breakout Ports 100-Gbps or 40-Gbps cable can be used on and ICX 7850 standalone units to break out certain 40-Gbps ports into four 10-Gbps subports and 100-Gbps ports into four 25-Gbps subports respectively. Configuring the CLI Banner RUCKUS