switch using the ipv6 unicast-routing command and must enable IPv6 on at least one interface by configuring an IPv6 address or explicitly enabling IPv6 on that interface. ICX7150 devices do not support tunnels or VRFs. The no form of the command disables IPv6 static route next-hop resolution through
Configuration Changes in PE Mode Before Joining the CB
Configuration Changes in PE Mode Before Joining the CB Configuration Changes in PE Mode Before Joining the CB Configuration Changes in PE Mode Before Joining the CB When the system reboots after you save and reload a Provisional-PE configuration on an ICX7150, ICX 7250, or ICX 7450 unit, the unit
Enabling priority flow control on an interface Enabling priority flow control on an interface Enabling priority flow control on an interface Follow these steps to enable PFC on an interface. PFC is supported only on RUCKUS ICX 7250, ICX 7450, and ICX 7750 devices. The ICX7150, ICX 7650, ICX 7850
SPX operation unit table SPX operation unit table SPX operation unit table The following MIB table objects display SPX-related information for each operational CB and PE unit. The following table objects are supported only on the Ruckus ICX7150, Brocade ICX 7250, Brocade ICX 7450, RUCKUS ICX 7650
. This method is described in Section 3.2 of RFC 4459. Inner packets can be fragmented before encapsulation, in such a manner that the encapsulated packet fits in the tunnel path MTU, which is discovered using PMTUD. This method is described in Section 3.4 of RFC 4459. By default, PMTUD is enabled. ICX7150 devices do not support tunnels.
oif-list and all keywords. device(config)# no ip multicast optimization oif-list all device(config)# no ipv6 multicast optimization oif-list all device(config)# write memory device(config)# exit device# reload Entry optimization is enabled by default on RUCKUS ICX7150, ICX 7250, ICX 7450, ICX 7550, ICX 7650, ICX 7750, and ICX 7850 devices for Layer 2 and Layer 3 multicast traffic.