show default values
Last Updated
Sep 03, 2026
08.0.90 The output for this command was updated to display information about the selected forwarding profile and the related scale numbers for ICX 7850 devices. 08.0.95 The output for this command was updated to not display information about the maximum number of DHCP snooping entries.
-
led
Last Updated
Sep 03, 2026
, and ICX 7850 devices. The default LED status is the status of the LEDs according to the current status mode, if the status mode is supported. If the status mode is not supported, the link status or port status is considered to be the default LED status. If the status of the port changes due to any
-
optical-monitor
Last Updated
Sep 03, 2026
no optical-monitor non-ruckus-optic-enable Optical transceivers are not monitored. alarm-interval Specifies the interval at which alarms and warning messages are sent. The default and minimum timer for ICX 7450, ICX 7550, ICX 7650, RUCKUS ICX 7750, and ICX 7850 devices is 8 minutes. The default
-
show bfd
Last Updated
Sep 03, 2026
show bfd show bfd show bfd Displays Bidirectional Forwarding Detection (BFD) information. show bfd User EXEC mode This command is supported for Ruckus ICX 7750 and ICX 7850 devices. The show bfd command displays the following information: Output Field Description BFD State Specifies whether BFD is
-
Support for Multicast Multi-VRF
Last Updated
Sep 03, 2026
specified VRF. The ip igmp max-group-address command replaces the system-max igmp-max-group-address command. For ICX 7850 and ICX 7550 devices, values are used from the forwarding profile. Refer to the forwarding-profile command in the RUCKUS FastIron Command Reference and the Configuration
-
Allocating TCAM Space
Last Updated
Sep 03, 2026
manual configuration of IPv4 routes. For the ICX 7850, values are used from the forwarding profile and there is no option to change these values. When a new profile is selected, the values from the new profile are applied. Refer to the forwarding-profile command in the Ruckus FastIron Command
-
Configuring Breakout Ports and Sub-Ports
Last Updated
Sep 03, 2026
breakout is configured. However, ICX 7850 does not need to be in store-and-forward mode for breakout to be functional. Configure sub-ports. device(config)#interface ethernet 1/1/11:1 to 1/1/11:4 In the example, port 1/1/11 has been configured for breakout into four 25 Gbps sub-ports. Sub-ports are
-
Configuring the share port level for an egress buffer profile
Last Updated
Sep 03, 2026
portion of the total memory. The configuration of the egress buffer share port level is supported only on the RUCKUS ICX 7150. For the RUCKUS ICX 7250, ICX 7450, ICX 7650, ICX 7750, ICX 7850, and ICX 7550 devices, you can change the queue share level for an individual queue which has a finer
-
neighbor bfd
Last Updated
Sep 03, 2026
IPv4 unicast VRF configuration mode BGP address-family IPv6 unicast VRF configuration mode This command is supported for Ruckus ICX 7750 and ICX 7850 devices. This command is supported for ICX 7850 devices only. It is recommended to use the default values. The no form of the neighbor { ip-address
-
neighbor bfd
Last Updated
Sep 03, 2026
IPv4 unicast VRF configuration mode BGP address-family IPv6 unicast VRF configuration mode This command is supported for Ruckus ICX 7750 and ICX 7850 devices. This command is supported for ICX 7850 devices only. It is recommended to use the default values. The no form of the neighbor { ip-address