qos egress-buffer-profile queue-share-level
Last Updated
Sep 03, 2026
buffers that can be used in a sharing pool. Eight levels are supported. queue-number Specifies the queue to apply the buffer limit to. There are eight hardware queues per port. Global configuration mode This command is supported only on Ruckus ICX 7250 and ICX 7450 devices. This command is not supported
-
Last Updated
Sep 03, 2026
. Campus Fabric mirroring overview Campus Fabric mirroring overview Mirroring in a Campus Fabric domain Mirroring in a Campus Fabric domain In a Campus Fabric domain, you can mirror ports in an ICX 7150 PE unit, an ICX 7250 PE unit, an ICX 7450 PE unit, or an ICX 7650 CB unit. Campus Fabric supports
-
show stack detail
Last Updated
Sep 03, 2026
one other stack unit. System uptime Indicates the amount of time that the stack unit has been running since the last reset. The System uptime is listed for each unit in the stack. The following example displays information on a full ICX 7450 stack containing 12 units, with six different models. device
-
show cable-diagnostics tdr
Last Updated
Sep 03, 2026
indicate a complete break in the pair or a short circuit. impedmis: The impedance is mismatched, indicating that different types of cables are joined together. This can lead to signal reflections and performance issues. If a port on a Ruckus ICX 7450 is connected to a Ruckus ICX 7750 device, the
-
show chassis
Last Updated
Sep 03, 2026
EXEC mode The following is sample output from the show chassis command executed on an ICX 7450 device. device# show chassis The stack unit 1 chassis info: Power supply 1 not present Power supply 2 (AC - Regular) present, status ok Model Number: 23-0000144-02 Serial Number: 07W Firmware Ver: A Power
-
Last Updated
Sep 03, 2026
. Campus Fabric mirroring overview Campus Fabric mirroring overview Mirroring in a Campus Fabric domain Mirroring in a Campus Fabric domain In a Campus Fabric domain, you can mirror ports in an ICX 7150 PE unit, an ICX 7250 PE unit, an ICX 7450 PE unit, or an ICX 7650, ICX 7750, or ICX 7850 CB unit
-
ACL Scaling
Last Updated
Sep 03, 2026
7850 ICX 7750 ICX 7650 ICX 7550 ICX 7450 ICX 7250 ICX 7150 Software Scale Maximum configurable standard numbered IPv4 ACLs 99 99 99 99 99 99 99 Maximum configurable extended numbered IPv4 ACLs 100 100 100 100 100 100 100 Maximum configurable standard named IPv4 ACLs 600 600 600 600 600 600 600
-
Auto-Enabling of PoE
Last Updated
Sep 03, 2026
in a stack, if the stack units have different PoE chip versions. For example, downgrade is not supported if the ICX 7450 stack has units with newer and older PoE chipsets. Beginning with FastIron 08.0.95j release, the ICX 7150-48ZP devices with new POE chipset does not support downgrade process. If
-
RUCKUS ICX Switch Port Extender Deployment Guide
Last Updated
Sep 02, 2026
]ICX7450-48 Router(config)# spx suggested-id 56 You can bring the operational PE unit back to the ICX 7450 standalone unit by using the spx unconfigure me command. [PE]local-18@ICX7450-24P Router# spx unconfigure me This unit will remove the PE startup file and reload as a standalone. Are you sure
-
RUCKUS ICX 7450 Switch Technical Specifications
Last Updated
Sep 02, 2026