-
OS Prompt Recovery Procedures
Last Updated
Sep 03, 2026
information on password recovery. This procedure is only supported on ICX 7150 devices. When FIPS mode is enabled, the image cannot be updated from uboot or OS prompt. If during an upgrade procedure, the ICX device enters the OS mode and does not exit, use the copy tftp flash command at the OS prompt to re
-
Configuring PoD on an interface
Last Updated
Sep 03, 2026
Configuring PoD on an interface Configuring PoD on an interface Configuring PoD on an interface Configuring PoD on an interface is supported on Ruckus ICX 7150 and Ruckus ICX 7250 ports when upgrading to 10-Gbps speed. To upgrade the ports from 1-Gbps to 10-Gbps speed, perform the following steps
-
telnet
Last Updated
Sep 03, 2026
Identifies the VE interface that must be used to reach the remote host. Privileged EXEC mode The telnet command establishes a Telnet connection from a device to a remote host using the console. To see the number of open Telnet sessions at any time, enter the show telnet command. RUCKUS ICX 7150-ES and
-
tunnel source
Last Updated
Sep 03, 2026
the other end of the tunnel is reachable. The source interface must have at least one IP address configured on it. ICX 7150 devices do not support tunnels. The following example configures the IP address 10.1.2.4 as the source address for a specific tunnel interface. device# configure terminal
-
Campus Fabric scalability
Last Updated
Sep 03, 2026
7250, or ICX 7150 devices are used as PE units, 1,728 ports are supported. Campus Fabric domain maximum configuration can be summarized as follows: 4 CB units (ICX 7650 stack) 32 ports per CB (32 X 4 for full CB stack) Maximum of 8 PE chains Maximum 16 stand-alone PEs (in addition to 8 PE chains
-
Protecting a unit from being discovered
Last Updated
Sep 03, 2026
to a PE unit accidentally. Follow these steps to prevent an ICX 7150, ICX 7250, or ICX 7450 device from being discovered and converted by the zero-touch or interactive-setup utility. Use the no form of the command to again make the device available for zero-touch configuration or interactive-setup
-
Campus Fabric Scalability
Last Updated
Sep 03, 2026
7250, or ICX 7150 devices are used as PE units, 1,728 ports are supported. Campus Fabric domain maximum configuration can be summarized as follows: 4 CB units (ICX 7650, ICX 7750, or ICX 7850 stack) 32 ports per CB (32 X 4 for full CB stack) Maximum of 8 PE chains Maximum 16 stand-alone PEs (in
-
Protecting a Unit from Being Discovered
Last Updated
Sep 03, 2026
to a PE unit accidentally. Follow these steps to prevent an ICX 7150, ICX 7250, or ICX 7450 device from being discovered and converted by the zero-touch or interactive-setup utility. Use the no form of the command to again make the device available for zero-touch configuration or interactive-setup
-
ACL Logging Upgrade Considerations
Last Updated
Sep 03, 2026
the respective bindings corresponding to the filter group and interface combination in the ingress direction after the upgrade. On RUCKUS ICX 7150, ICX 7550, ICX 7650, and ICX 7850 devices, ACL logging is not supported for ACLs applied to outbound traffic.
-
Configuration Notes for ACL Logging
Last Updated
Sep 03, 2026
and VLANs. If you remove an egress ACL with rules enabled for logging, although new packets are not logged, previous logs will be in the syslog when the sample timer expires. The log count may not be accurate for broadcast traffic or for unknown unicast traffic. On RUCKUS ICX 7150, RUCKUS ICX 7550