Change the Settings

N+1 Configuration and Hot Upgrade can be performed only when SSH is enabled.
  1. From the main menu, click Admin.
  2. In the left navigation pane, click Settings.

    Settings Page

  3. Enable SSH.
    Note: If SSH is disabled, the N+1 configuration cannot be established and the following error is observed.

    Showing Error on Disabling SSH

  4. The Log Level Settings consists of the below list items. By deafault, select INFO and click Apply.
    • DEBUG - To debug a problem in IoT controller, relatively detailed tracing used by application developers for troubleshooting. Logs a message with level DEBUG on this logger.
    • INFO - Informational messages that might make sense to end users and system administrators and highlight the progress of the application. Logs a message with level INFO on this logger.
    • WARNING - Warning logs indicate that an unexpected event has occurred in an application that may disrupt or delay other processes. Logs a message with level WARNING on this logger.
    • ERROR - Error events of considerable importance that will prevent normal program execution but might still allow the application to continue running. Logs a message with level ERROR on this logger.
  5. The BLE Radio Scan Settings consists of the Scan Mode and Discovery Mode. By default, Passive and Discoverable modes are set. You can configure the Scan Mode to operate in Active mode. In the Active mode, gateways send scan requests and expect a SCAN_RSP packet in response to each broadcasted packet. Click Apply to accept the settings.
    For more detatils, refer to the topic BLE Radio Scan Settings.