Ruckus ICX 7450 Switch Technical Specifications

This document highlights the features and specifications for the Ruckus ICX 7450 Switch.

System specifications

System component Description

Enclosure

Stackable up to 12 switches per stack, chassis-mountable in a standard 2 or 4-post rack

Power supplies

Dual redundant, hot-swappable power supplies supported with 250 W AC intake or exhaust airflow for non-PoE switches, and 1000 W AC with intake or exhaust airflow for PoE switches. Shipping bundle has one power supply and one fan unit.

Fans

One dual redundant, hot-swappable fan unit with intake or exhaust airflow

Cooling

Forced-air cooling; front-to-back or back-to-front

System architecture

Nonblocking shared memory switch

ICX 7450-24: 24 1-GbE RJ-45 ports, four 10-GbE SFP+ Uplink/Stacking ports, two 40-GbE QSFP+ stacking ports, one power supply, and one fan unit

ICX 7450-24P: 24 1-GbE RJ-45 ports (supporting PoE, PoE+, High PoE, PoH), four 10-GbE SFP+ Uplink/Stacking ports, two 40-GbE QSFP+ stacking ports, one power supply, and one fan unit

ICX7450-32ZP: 24 1-GbE RJ-45 ports, 8 2.5-GbE RJ-45 ports (supporting PoE, PoE+, High PoE, PoH), four 10-GbE SFP+ Uplink/Stacking ports, two 40-GbE QSFP+ stacking ports, one power supply, and one fan unit.

ICX 7450-48: 48 1-GbE RJ-45 ports, four 10-GbE SFP+ Uplink/Stacking ports, two 40-GbE QSFP+ stacking ports, one power supply, and one fan unit

ICX 7450-48P: 48 1-GbE RJ-45 ports (supporting PoE, PoE+, High PoE, PoH), four 10-GbE SFP+ Uplink/Stacking ports, two 40-GbE QSFP+ stacking ports, one power supply, and one fan unit.

ICX 7450-48F: Eight 1-GbE SFP ports, four 10-GbE SFP+ Uplink/Stacking ports, two 40-GbE QSFP+ stacking ports, one power supply, and one fan unit

System processors

BCM56548 with dual-core ARM Cortex A9 processor running at 1 GHz

Ethernet

These are standard modules for shipping bundles. For ICX 7450-24/24P/32ZP/48/48P/48F non-bundled switches, expansion modules need to be ordered separately.

System component Description Maximum ports supported

40 GbE QSFP+ ports

One 40-GbE QSFP+ stacking or uplink port

3 (slot 2-4) for ICX 7450-24/24P

2 (slot 3-4) for ICX 7450-48/48P/48F/32ZP

10 GbE SFP+ ports

Four 10-GbE SFP+ uplink or stacking ports

12 (slot 2-4)

10 GbE copper ports (optional modules)

Four 10G RJ-45 uplink ports

12 (slot 2-4)

1 GbE SFP ports (optional modules)

Four 1G SFP uplink ports

4 (slot 2)

1 GbE RJ-45 front panel ports

24 1-GbE RJ-45 ports for ICX 7450-24/24P

48 1-GbE RJ-45 ports for ICX 7450-48/48P

24/48 (slot 1)

1 GbE SFP front panel ports

48 1-GbE SFP for ICX 7450-48F

48 (slot 1)

Ethernet management port

One RJ-45 port with 10/100/1000 Mbps auto-negotiating capability

N/A

LEDs

System component Description

Switch status and management

Five LED states to indicate switch status (green and amber)

Three LED states to indicate power supply status (green and amber)

Four LED states for diagnostics (green and amber)

Six LED states to indicate stacking-relates status (green and amber)

Five LED states to indicate module and module power status (green and amber)

Ports

28 LED states to indicate the port status (green and amber)

Other

System component Description

Serial cable

Mini-USB to RJ-45

RJ-45 to DB9 adapter

1

AC power cord, power clip

For ICX 7450-24-E, 24P-E, 32-ZP, 48-E, 48P-E and 48F-E units

Weight and physical dimensions

With one power supply, one fan assembly, two stacking modules, and one 10-GbE media module.

Model Height Width Depth Weight (with basic modules) Fully loaded weight (no transceivers)

ICX 7450-24

4.37 cm

1.72 inches

40.00 cm

17.32 inches

39.37 cm

15.50 inches

6.40 kg

14.11 lb

8.57 kg

18.89 lb

ICX 7450-24P

4.37 cm

1.72 inches

40.00 cm

17.32 inches

39.37 cm

15.50 inches

6.90 kg

15.21 lb

9.02 kg

19.89 lb

ICX 7450-32ZP

4.37 cm

1.72 inches

40.00 cm

17.32 inches

39.37 cm

15.50 inches

7.14 kg

16.05 lb

8.91 kg

19.69 lb

ICX 7450-48

4.37 cm

1.72 inches

40.00 cm

17.32 inches

39.37 cm

15.50 inches

6.50 kg

14.33 lb

8.74 kg

19.2 lb

ICX 7450-48P

4.37 cm

1.72 inches

40.00 cm

17.32 inches

39.37 cm

15.50 inches

7.10 kg

15.65 lb

9.21 kg

20.30 lb

ICX 7450-48F

4.37 cm

1.72 inches

40.00 cm

17.32 inches

39.37 cm

15.50 inches

6.80 kg

14.99 lb

8.94 kg

19.71 lb

Environmental requirements

Condition Operational Non-operational

Ambient temperature

-5°C to 50°C (23°F to 122°F)

Note: Maximum operation temperature of 50 °C applies to sea level and decreases by 1°C for every 1000 feet altitude increase per NEBS rule. If Back-to-Front air flow is chosen and only a single fan is in service, maximum operation temperature decreases by 5°C.

-40°C to 70°C (-40°F to 158°F)

Relative humidity (non-condensing)

10% to 90% at 50°C (122°F)

5% to 95% at 70°C (158°F)

Altitude (above sea level)

0 to 3,048m (10,000 ft)

0 to 12,000 m (39,370 ft)

Shock

20 G, 11 ms, half-sine wave

33 G, 11 ms, half-sine wave

Vibration

1 G sine, 0.4 grms random, 5-500 Hz

2.4 G sine, 1.1 grms random, 5-500 Hz

Airflow

Nominal: 5-7 cfm; Maximum: 17-20 cfm

N/A

Heat dissipation (+/- 5%)

Note: Refer to “Power consumption (typical configuration)” and “Power consumption (maximum configuration)” for detailed information on heat dissipation.

N/A

Operating noise

ICX 7450-24-E: 46 dBA

ICX 7450-24P-E: 49 dBA

ICX 7450-32ZP: unknown dBA

ICX 7450-48-E: 47 dBA

ICX 7450-48P-E 49 dBA

ICX 7450-48F-E: 46 dBA

N/A

MTBF @ 25°C

ICX 7450-24-E: 399,973 Hours

ICX 7450-24P-E: 317,719 Hours

ICX 7450-32ZP: unknown Hours

ICX 7450-48-E: 376,635 Hours

ICX 7450-48P-E: 297,862 Hours

ICX 7450-48F-E: 330,154 Hours

N/A

Power supply specifications (per PSU)

Power supply model Maximum output power rating (DC) Input voltage Input line frequency Maximum input current Input line protection Maximum inrush current

AC RPS15-E

250 W

100-240 VAC

50-60Hz

4 A

Fuses

35 A

AC RPS15-I

250 W

100-240 VAC

50-60Hz

4 A

Fuses

35 A

AC RPS16-E

1000 W

100-240 VAC

50-60Hz

11.8 A

Fuses

35 A

AC RPS16-I

1000 W

100-240 VAC

50-60Hz

11.8 A

Fuses

35 A

Power consumption (typical configuration)

All 1-Gbps and two 10-Gbps ports are linked up, loading with 10% traffic rate, and no PoE load. Two fan FRUs, 4x10GC ports are linked up, and no stacking module. Fans at nominal speed.

ICX7450-32ZP: 24 1-Gbps ports and eight 2.5-Gbps ports. Slot1: Empty, Slot2: 4x10GF, Slot3: 4x10GF ports are linked UP, loading with 10% traffic rate. Two fans at nominal speed.

Model name (Input power +/- 5 %) @100 VAC input @200 VAC input @-48 VDC Minimum number of power supplies Notes

ICX 7450-24

88.5 W

302 BTU/hr

87.6 W

299 BTU/hr

80.6 W

276 BTU/hr

1 x 250 W AC

1 x 510 W DC

1 PSU

100.1 W

342 BTU/hr

99.2 W

339 BTU/hr

85.3 W

291 BTU/hr

1 x 250 W AC

1 x 510 W DC

2 PSUs

ICX 7450-24P

95.3 W

325 BTU/hr

94.1 W

321 BTU/hr

82.6 W

282 BTU/hr

1 x 1000 W AC

1 x 510 W DC

1 PSU,

no PoE load

112.9 W

386 BTU/hr

111.7 W

381 BTU/hr

87.58 W

291 BTU/hr

1 x 1000 W AC

1 x 510 W DC

2 PSUs,

no PoE load

ICX 7450-32ZP

120.46 W

411.14 BTU/hr

118.59 W

404.76 BTU/hr

105.27 W

359.29 BTU/hr

118.59 W

404.76 BTU/hr

110.4 W

376.8 BTU/hr

130.57 W

445.65 BTU/hr

128.32 W

437.97 BTU/hr

109.31 W

373.08 BTU/hr

132.71 W

452.95 BTU/hr

114.31 W

390.15 BTU/hr

ICX 7450-48

117.6 W

402 BTU/hr

115.9 W

442 BTU/hr

107.6 W

367 BTU/hr

1 x 250 W AC

1 x 510 W DC

1 PSU

129.4 W

451 BTU/hr

128.4 W

438 BTU/hr

115.94 W

396 BTU/hr

1 x 250 W AC

1 x 510 W DC

2 PSUs

ICX 7450-48P

129.7 W

443 BTU/hr

143 W

488 BTU/hr

115.1 W

393 BTU/hr

1 x 1000 W AC

1 x 510 W DC

1 PSU,

no PoE load

128.2 W

438 BTU/hr

141.1 W

482 BTU/hr

118.82 W

406 BTU/hr

1 x 1000 W AC

1 x 510 W DC

2 PSUs,

no PoE load

ICX 7450-48F

141.4 W

420 BTU/hr

139.6 W

477 BTU/hr

129.2 W

441 BTU/hr

1 x 250 W AC

1 x 510 W DC

1 PSU

152.8 W

522 BTU/hr

151.6 W

518 BTU/hr

132.78 W

474 BTU/hr

1 x 250 W AC

1 x 510 W DC

2 PSUs

Power consumption (maximum configuration)

All 1-Gbps and two 10-Gbps ports are linked up, loading with 100% traffic rate, and 100% PoE load. Two fan FRUs, 4x10GC ports are linked up, and no stacking module. Fans at high speed.

ICX7450-32ZP: 24 1-Gbps ports and eight 2.5Gbps ports. Slot1: Empty, Slot2: 4x10GF, Slot3: 4x10GF are linked UP, 100% traffic and PoE load.

Model name (Input power +/- 5 %) @100 VAC input @200 VAC input @-48 VDC Minimum number of power supplies Notes

ICX 7450-24

119.7 W

409 BTU/hr

118.5 W

405 BTU/hr

113.8 W

388 BTU/hr

1 x 250 W AC

1 x 510 W DC or 2 x 510 W DC

1 PSU

134.9 W

461 BTU/hr

133 W

454 BTU/hr

125.24 W

428 BTU/hr

1 x 250 W AC

1 x 510 W DC or 2 x 510 W DC

2 PSUs

ICX 7450-24P

947 W

3232 BTU/hr

919 W

3137 BTU/hr

387.2 W

1322 BTU/hr

1 x 1000 W AC

1 x 510 W DC or 2 x 510 W DC

1 PSU

1402 W

4785 BTU/hr

1374 W

4690 BTU/hr

669.06 W

2284 BTU/hr

2 x 1000 W AC

1 x 510 W DC or 2 x 510 W DC

2 PSUs required for PoE loading

ICX 7450-32ZP

167.1 W

570.33 BTU/hr

164.06 W

559.95 BTU/hr

145.98 W

498.24 BTU/hr

1 x 1000 W AC

1 x 510 W DC or 2 x 510 W DC

1 PSU

1853.08 W

6324.71 BTU/hr

1763.55 W

6019.14 BTU/hr

698.79 W

2385.03 BTU/hr

2 x 1000 W AC

1 x 510 W DC or 2 x 510 W DC

2 PSUs required for PoE loading

ICX 7450-48

154.4 W

527 BTU/hr

151.8 W

518 BTU/hr

146.1 W

499 BTU/hr

1 x 250 W AC

1 x 510 W DC or 2 x 510 W DC

1 PSU

168.8 W

576 BTU/hr

167.4 W

572 BTU/hr

156.68 W

535 BTU/hr

1 x 250 W AC

1 x 510 W DC or 2 x 510 W DC

2 PSUs

ICX 7450-48P

998 W

3406 BTU/hr

958 W

3270 BTU/hr

421.4 W

1438 BTU/hr

1 x 1000 W AC

1 x 510 W DC or 2 x 510 W DC

1 PSU

1809 W

6174 BTU/hr

1769 W

6038 BTU/hr

704.12 W

2403 BTU/hr

1 x 1000 W AC

1 x 510 W DC or 2 x 510 W DC

2 PSUs required for PoE loading

ICX 7450-48F

178.3 W

609 BTU/hr

175.7 W

606 BTU/hr

167.1 W

570 BTU/hr

1 x 250 W AC

1 x 510 W DC or 2 x 510 W DC

1 PSU

196.4 W

670 BTU/hr

194.1 W

663 BTU/hr

177.64 W

606 BTU/hr

1 x 250 W AC

1 x 510 W DC or 2 x 510 W DC

2 PSUs

Power consumption (modules)

Module name Module description Power consumption

ICX7400-4X1GF

4-port 1 GbE SFP expansion module

Typical = 5.40 W

Maximum = 5.76 W

ICX7400-4X10GF

4-port 1/10 GbE SFP+ expansion module

Typical = 12.96 W

Maximum = 15.72 W

ICX7400-4X10GC

4-port 1/10 GbE copper expansion module

Typical = 18.72 W

Maximum = 20.76 W

ICX7400-1X40GQ

1-port 40 GbE QSFP+ data uplink/stacking module

Typical = 5.64 W

Maximum = 7.38 W

ICX-FAN10-E

Power supply exhaust airflow fan (two fans required if two power supplies are used)

Typical = 4.68 W

Maximum = 16.68 W

ICX-FAN10-I

Power supply intake airflow fan (two fans required if two power supplies are used)

Typical = 4.68 W

Maximum = 16.68 W

Data port specifications (Ethernet)

This table lists the ports for switch bundles. Other port combinations can be used for non-bundled switches. All the switches also support 10/100M on 1GbE ports. -32ZP supports 100M at 2.5 GbE ports.

Model Port type Number (in module) Description

ICX 7450-24

40 GbE

2 (ICX7400-1X40GQ)

QSFP+ stacking ports, compatible with LR4 or SR4 optical transceivers, or direct attached copper cable

10 GbE

4 (ICX7400-4X10GC)

SFP+ uplink ports, compatible with ER, LR, LRM, SR, ZR or USR optical transceivers

1 GbE

24 (slot 1)

RJ-45 ports

ICX 7450-24P

40 GbE

2 (ICX7400-1X40GQ)

QSFP+ stacking ports, 40 Gbps, compatible with LR4 or SR4 optical transceivers, or direct attached copper cable

10 GbE

4 (ICX7400-4X10GC)

SFP+ uplink ports, compatible with ER, LR, LRM, SR, ZR or USR optical transceivers

1 GbE

24 (slot 1)

RJ-45 ports with PoE support

ICX 7450-32ZP

40 GbE

2 (ICX7400-1X40GQ)

QSFP+ stacking ports, 40 Gbps, compatible with LR4 or SR4 optical transceivers, or direct attached copper cable

10 GbE

4 (ICX7400-4X10GC)

SFP+ uplink ports, compatible with ER, LR, LRM, SR, ZR or USR optical transceivers

2.5 GbE

8 (slot 1)

RJ-45 ports with PoE support

1 GbE

24 (slot 1)

RJ-45 ports with PoE support

ICX 7450-48

40 GbE

2 (ICX7400-1X40GQ)

QSFP+ stacking ports, compatible with LR4 or SR4 optical transceivers, or direct attached copper cable

10 GbE

4 (ICX7400-4X10GC)

SFP+ uplink ports, compatible with ER, LR, LRM, SR, ZR or USR optical transceivers

1 GbE

48 (slot 1)

RJ-45 ports

ICX 7450-48P

40 GbE

2 (ICX7400-1X40GQ)

QSFP+ stacking ports, compatible with LR4 or SR4 optical transceivers, or direct attached copper cable

10 GbE

4 (ICX7400-4X10GC)

SFP+ uplink ports, compatible with ER, LR, LRM, SR, ZR or USR optical transceivers

1 GbE

48 (slot 1)

RJ-45 ports with PoE support

ICX 7450-48-F

40 GbE

2 (ICX7400-1X40GQ)

QSFP+ stacking ports, compatible with LR4 or SR4 optical transceivers, or direct attached copper cable

10 GbE

4 (ICX7400-4X10GC)

SFP+ uplink ports, compatible with ER, LR, LRM, SR, ZR or USR optical transceivers

1 GbE

48 (slot 1)

SFP ports, compatible with 100Base-FX IR or LR SFP optic for SMF, 100Base-FX SFP optic MMF, 1000Base-BXD SFP optic SMF, 1000Base-BXU SFP optic SMF, 1000Base-LHA SFP optic SMF, 1000Base-LX SFP optic SMF, 1000Base-SX SFP optic MMF, 1000BASE-TX SFP Copper

Serial port specifications (pinout mini-USB)

Pin Signal Description

1

Reserved

Not used

2

UART0_TX

Debug port (data transmitted by ICX)

3

UART0_RX

Console port (data received by ICX)

4

Reserved

Not used

5

GND

Ground

Serial port specifications (pinout RJ-45)

Pin Signal Description

1

Not supported

N/A

2

Not supported

N/A

3

UART1_TXD

Transmit data to ICX

4

GND

Logic ground

5

Not supported

N/A

6

UART1_RXD

Receive data from ICX

7

Not supported

N/A

8

Not supported

N/A

Serial port specifications (protocol)

Parameter Value

Baud

9600

Data bits

8

Parity

None

Stop bits

1

Flow control

None

Memory specifications

Memory Type Size

Main memory

DDR3

2 GB

Boot Flash

NOR flash

8 MB

Compact Flash

eUSB NAND flash

2 GB

eUSB Drive

USB

2 GB

Regulatory compliance (EMC)

  • FCC Part 15, Subpart B (Class A)
  • EN 55022 (CE mark) (Class A)
  • EN 55024 (CE mark) (Immunity) for Information Technology Equipment
  • ICES-003 (Canada) (Class A)
  • AS/NZ 55022 (Australia) (Class A)
  • VCCI (Japan) (Class A)
  • EN 61000-3-2
  • EN 61000-3-3
  • EN 61000-6-1

Regulatory compliance (safety)

  • CAN/CSA-C22.2 No. 60950/UL 60950
  • EN 60825 Safety of Laser Products
  • EN 60950/IEC 60950 Safety of Information Technology Equipment

Regulatory compliance (environmental)

  • 2014/35/EU and 2014/30/EU
  • 2011/65/EU – Restriction of the use of certain hazardous substance in electrical and electronic equipment (EU RoHS)
  • 2012/19/EU – Waste electrical and electronic equipment (EU WEEE)
  • 94/62/EC – packaging and packaging waste (EU)
  • 2006/66/EC – batteries and accumulators and waste batteries and accumulators (EU battery directive)
  • 1907/2006 of the European Parliament and of the Council of 18 December 2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (EU REACH)
  • Section 1502 of the Dodd-Frank Wall Street Reform and Consumer Protection Act of 2010 – U.S. Conflict Minerals
  • 30/2011/TT-BCT – Vietnam circular
  • SJ/T 11363-2006 Requirements for Concentration Limits for Certain Hazardous Substances in EIPs (China)
  • SJ/T 11364-2006 Marking for the Control of Pollution Caused by EIPs (China)