Slot Profile
Configures and modifies the slot 2 module ports to uplink 40-Gbps and 100-Gbps port on RUCKUS ICX 7550-24ZP and ICX 7550-24F devices. Only POST operation is supported.
restconf/operations/slot-profile
Supported HTTP Operations
POST method to configure the uplink-40-Gbps is:
URL: https://<host>/restconf/operations/slot-profile
Request body:
{
"icx-openconfig-platform-aug:input":{
"slot-num": 2,
"uplink-40g" : true
}
}
Response body: None
POST method to set the port to default slot profile is:
Request body:
{
"icx-openconfig-platform-aug:input":{
"slot-num": 2,
"uplink-40g" : false
}
}
Response body: None
The slot number indicates the slot number of the ICX 7550-24ZP and ICX 7550-24F devices which is module 2. The uplink-40g is set to true if you want to configure the slot profile to uplink-40-Gbps speed and set to false if you want a default slot profile.