Performing a FIPS Self-test
Use the FIPS self-test to verify the sanity of FIPS software.
For more information on the FIPS self-test, refer to Running FIPS self-test.
Note: During FIPS self-test, the CPU usage is high. The
fips self-tests command should only be used prior to the device being placed into FIPS operational
or administrative modes. Using the
fips self-tests command in FIPS operational or administrative mode may result in the device rebooting
as per the FIPS criteria.
- From the Privileged EXEC level of the CLI on the console, use the
fips self-testscommand to verify that the FIPS Software and Firmware Integrity Test passes. - The following example shows the FIPS Software and Firmware Integrity Test as passed:
device# fips self-tests Running FIPS Power On Self Tests and Software/Firmware Integrity Test. FIPS Power On Self Tests and Software/Firmware Integrity tests successful. .....<output truncated>.......
If the software integrity test fails, make sure that the correct signature file was copied for the correct image file and version, and recopy as needed. If the problem persists, contact RUCKUS technical support.
Note: The FIPS self-test must pass before the configuration is saved and the device is reloaded.
Note: The FastIron device will cease operation and force a reboot if the self-test
fails.