Connecting to an OpenFlow Controller
To connect to an OpenFlow Controller in active mode, enter the following command:
device(config)# openflow controller ip-address 10.2.3.4
the IP address is the address of the OpenFlow Controller and SSL encryption is used by default. Also, the OpenFlow connection uses TCP port 6633.
To connect to an OpenFlow Controller in the passive mode, enter the following command:
device(config)# openflow controller passive no-ssl
You can optionally specify the TCP port to be used for the connection. By default, the device accepts the connection from a controller with any IP address. However, you can provide an IP address to limit which controller can connect to the device.
Use the
no
form of the command to remove a passive connection. Passive mode connections are
intended for testing environments and not recommended for production environments.