Configuring a port to the egress queue drop counters
The
RUCKUS ICX 7150 has only one set of egress queue drop counters and can monitor only one port for
the incrementing of the counters. By default, the device monitors the local CPU port
for control packet drops. However, you can configure the device to monitor a different
port for packet drops.
On the RUCKUS ICX 7250, ICX 7450, ICX 7750, ICX 7850, and ICX 7550 devices, each port has its own set of drop counters.
Perform the following steps to configure a port that the device monitors for the egress queue drop counters.
- Enter global configuration mode.
- Configure the port that the device monitors for the egress queue drop counters.
In this step, the counters are associated to port 1/1/12.
- Return to privileged EXEC mode.
- Verify the configuration
- Save the configuration.
Egress queue drop counters configuration example
device# configure terminal device(config)# qos monitor-queue-drop-counters 1/1/12 device# write memory
To display the queue drop counters, use the
show interfaces ethernet command for the port.