Creating a PSK in an Existing eDPSK Pool
You can manually generate DPSKs from within a configured eDPSK pool.
- In the Cloudpath UI, go to Configuration > DPSK Pools, then expand the pool from which you want to generate a DPSK. In this example, the DPSK is called "DPSK Pool 17."
- Click Add DPSK.
- In the ensuing screen, configure the values for the new DPSK, and click
Save when you are done. The figure below shows sample data, followed by descriptions of
the various fields.
- Display Name: Provide a descriptive name; the name is visible to administrators only.
- Description: Optionally, you can describe the DPSK; for example, you might want to list the device type to which you plan to assign this DPSK.
- Pre-Shared Key: This is the auto-generated key, which adheres to the character limit
and character type configured for the pool.
Note: Should you choose to manually specify a pre-shared key, the key must be unique to the pool and between 8-63 characters in length.
- Enforce Expiration Date: This field is checked by default. This means that the DPSK will expire on the date shown in the "Expiration Date" field, which is determined by the configuration for the corresponding eDPSK pool. However, you can un-check this box, which means that the DPSK will not expire.
- Restrict SSID(s): This field is unchecked by default, which means that the allowable SSIDs for this DPSK are the same as the SSIDs configured for the corresponding pool. However, you can further restrict this SSID list for the DPSK by checking this field, then entering a subset of the eDPSK pool's SSIDs into the "SSID(s)" popup box.
- Override Device Count Limit: By default, this box is unchecked, which means that the DPSK uses the device count limit specified within the eDPSK pool. If checked, however, this DPSK can have its own device count limit that you specify in the popup "Device Count Limit" box.
- Override VLAN ID: By default, this box is unchecked, which means that the DPSK uses the VLAN ID specified within the eDPSK pool. If checked, you can specify a VLAN ID in the popup "VLAN ID" field that will override the VLAN ID specified within the eDPSK pool. For example, if you specify an Override VLAN ID of 10, the RADIUS reply (access-accept) for the DPSK will contain the attributes (tunnel-type, tunnel-medium-type, private-tunnel-group-id) to set the VLAN to 10, regardless of whether the VLAN ID field for the pool is populated or empty.
- After you have saved the DPSK, the newly added DPSK is shown as part of the pool. Check that the information for the DPSK is what you want. An example is shown below, where a DPSK named "Device Group 10" has been added to DPSK Pool 17:
%20Confi_v1_GUID-881C7C9C-D4D6-4EAB-9EB7-A845178B17A5/cp_54_edpsk_after_new_pool_creation2=GUID-98D19AEE-BDF5-462D-89E4-FBDF05D49182=1=en-US=Low.png)
%20Confi_v1_GUID-881C7C9C-D4D6-4EAB-9EB7-A845178B17A5/cp_54_edpsk_create_dpsk=GUID-B3DCA0EC-588B-4ACE-A549-7109A43CA1C8=1=en-US=Low.png)
%20Confi_v1_GUID-881C7C9C-D4D6-4EAB-9EB7-A845178B17A5/cp_54_edpsk_after_dpsk_added2=GUID-F033C148-CE45-431C-B978-E5C90487D465=1=en-US=Low.png)