Replacing a Fiber-Optic Transceiver

You can replace a fiber-optic SFP+ transceiver while the device is powered on and running.

While replacing a fiber-optic module, you must wear an ESD wrist strap with a plug that can be inserted in the ESD connector on the device.

Danger: For safety reasons, the ESD wrist strap should contain a series 1 megohm resistor.

To replace a transceiver from an SFP+ slot, complete the following steps.

  1. Put on the ESD wrist strap and ground yourself by attaching the clip end to a metal surface (such as an equipment rack).
  2. Disconnect the cable connector from the port connector.
  3. Unlock the transceiver by pulling the bail latch forward, away from the front panel of the module. This unlocks the module from the front panel.

    Unlocking the bail latch

    1. Bail latch
    Note: On 1000Base-SX ports, the bail latch is enclosed in a black sleeve, and on 1000Base-LX ports, the bail latch is enclosed in a blue sleeve.
  4. Grasp the bail latch and pull the transceiver out of the port.

    Removing the fiber-optic module

  5. Store the transceiver in a safe, static-free place or in an anti-static bag.
  6. If you are installing a new module or replacing a module, install the new module in the port.