ruckusSZCPUUsageThresholdExceededTrap

ruckusSZCPUUsageThresholdExceededTrap

Object Name

ruckusSZCPUUsageThresholdExceededTrap

Object Identifier

.1.3.6.1.4.1.25053.2.11.1.6

Trap Severity

Critical

Bindings

ruckusSZEventSeverity

ruckusSZEventCode

ruckusSZEventType

ruckusSZEventNodeName

ruckusSZEventMacAddr

ruckusSZCPUPerc

Description

Triggered by the SmartZone CPU threshold exceeded event. The usage percentage threshold can be configured as 60% to 90%. This trap is sent if the usage percentage exceeds the configured threshold. The event severity, event code, event type, node name, MAC address and CPU usage percentage are displayed.

Generated by Event Code

950:cpuThresholdExceeded

Cleared by SNMP Trap

This SNMP trap is cleared by ruckusSZCPUUsageThresholdBackToNormalTrap (.1.3.6.1.4.1.25053.2.11.1.42)

Cleared by Matching

ruckusSZEventMacAddr (.1.3.6.1.4.1.25053.2.11.2.20.0)