PoE Power Management Methods
The following PoE power management (PM) methods are applicable for the , , and devices:
Static PM
In static PM, power gets reserved to every powered device (PD) connected on switch ports. New PDs will not get powered if the power reservation is not possible, even if total consumption is less than the total power budget. The PDs will not lose power as long as unit power budget is not changed. Power budget can get changed when power supply units are removed or added, budget can also get changed with fanless mode configuration.
Dynamic PM
In dynamic PM, power is not reserved for any ports. PDs are powered up automatically until the total power consumption is within the ICX device's total power budget. If the power consumption is increased, either by increasing the power consumption of connected PDs or by adding new PDs, the ICX devices keeps the total power consumption within the total power budget by immediately shutting down any PDs with low priority ports, or, if all ports have the same priority, shutting down PDs attached to higher-numbered ports.
Hybrid PM
In hybrid PM, some PDs will have power reservation and other PDs will not have power reservation.
To enable the hybrid PM behavior, you
must configure dynamic PM for the unit and then configure inline power ethernet
unit/slot/port priority 1 for the ports that require Static PM and
inline power ethernet
unit/slot/port priority 2 or inline power ethernet
unit/slot/port priority 3 for the ports that require Dynamic PM.