Checking RUCKUS One Connection Status
ICX switches have an LED that indicates when the device is managed from RUCKUS One. The following table interprets the LED status. Refer to the FastIron hardware installation guide for the specific ICX device for more information.
RUCKUS One LED Status
| Connection State | LED Status / Color |
|---|---|
| Connected | Solid Green |
| Attempting to connect (Connecting) | Slow flash green (one flash every two seconds) |
| Disconnected | Off |
| Receiving configuration from cloud | Fast flashing green (two flashes every seconds) |
The show manager
status command indicates when an ICX switch is managed
from RUCKUS One. The Operation Status: Enabled field indicates that the ICX
switch is connected to RUCKUS One, and the State: NATS CONNECTED field
indicates the ICX switch is being managed from RUCKUS One.
When the ICX switch is disconnected from RUCKUS One and managed locally, the Operation Status: Disabled, State: Disabled, and Previous State: NATS CONNECTED fields are displayed.
When "Manager mode: ACX" is displayed, the ICX device is managed by RUCKUS One. If "Manager mode: SZ" is displayed, the ICX device is managed by a SmartZone server.
The following example connects an ICX device to RUCKUS One.
ICX# show manager status ============ MGMT Agent State Info =================== Manager mode: ACX Config Status:Enabled Operation Status:Enabled State:NATS CONNECTED Prev State:NATS CONNECTING Event:ACX_HEARTBEAT_EVENT SWR List : device.ruckus.cloud 34.66.194.67 SWR fqdn : DNS List : Active FQDN List : None Backup FQDN List : None Active List : None Active List IPV6 : None DHCP Option 43 : No DHCP Opt 43 List : None Backup List : None Backup List IPV6 : None Merged List : device.ruckus.cloud 34.66.194.67 ACX Server Used : device.ruckus.cloud Port List : 987 Server Port Used : 443 SWR host : sw-registrar.ruckuswireless.com SWR discovery retry cnt : 0 SWR host retry time : 0 Query Status : Initiated NATS Tunnel Status -: Tunnel Status : NATS CONNECTED Websocket Port : 4222 NATS Port : 7681 RPCLI Status : None ACX Hbt Count : 60408 ACX JWT Renew Count : 4 Timer Status :- Manager Query Timer Status : None Manager heartbeat Timer Status : Running Manager JWT Renewal Timer Status : Running ACX JWT Renewal Time : 2023-05-19 18:13:22
ICX# manager disconnect Manager Disconnect Initiated... ICX# show manager status ============ MGMT Agent State Info =================== Manager mode: ACX Config Status:Enabled Operation Status:Disabled State:DISABLED Prev State:NATS CONNECTED Event:ACX_DISABLE_EVENT SWR List : device.ruckus.cloud 34.66.194.67 SWR fqdn : DNS List : Active FQDN List : None Backup FQDN List : None Active List : None Active List IPV6 : None DHCP Option 43 : No DHCP Opt 43 List : None Backup List : None Backup List IPV6 : None Merged List : device.ruckus.cloud 34.66.194.67 ACX Server Used : Port List : 987 Server Port Used : 443 SWR host : sw-registrar.ruckuswireless.com SWR discovery retry cnt : 0 SWR host retry time : 0 Query Status : Not Initiated NATS Tunnel Status -: Tunnel Status : None Websocket Port : 4222 NATS Port : 7681 RPCLI Status : None ACX Hbt Count : 60413 ACX JWT Renew Count : 4 Timer Status :- Manager Query Timer Status : None Manager heartbeat Timer Status : None Manager JWT Renewel Timer Status : None
Refer to the show manager
status command in the RUCKUS FastIron
Command Reference for more information.