Downgrading a Stack to a Release Prior to FastIron 09.0.10a
Last Updated
Sep 03, 2026
, copy the old startup-config file you saved previously back to the ICX device. The following example downgrades an ICX 7550 device by copying the file named saved_startup_08095 from the server at the specified IP address and saving it as startup-config. ICX7550-48ZP Router# copy tftp startup-config
-
Downgrading a Stack to a Release Prior to FastIron 09.0.10a
Last Updated
Sep 03, 2026
, copy the old startup-config file you saved previously back to the ICX device. The following example downgrades an ICX 7550 device by copying the file named saved_startup_08095 from the server at the specified IP address and saving it as startup-config. ICX7550-48ZP Router# copy tftp startup-config
-
ACL Logging Upgrade Considerations
Last Updated
Sep 03, 2026
upgrade, then logging will be enabled for the respective bindings corresponding to the filter group and interface combination in the ingress direction after the upgrade. On RUCKUS ICX 7150, ICX 7550, ICX 7650, and ICX 7850 devices, ACL logging is not supported for ACLs applied to outbound traffic.
-
AP LED Behavior
Last Updated
Sep 22, 2026
The network is down. AIR Always off Not used Switch LED Behavior For detailed information on Switch LED behavior, refer to the relevant hardware installation guide: https://docs.commscope.com/bundle?labelkey=icxswitches. ICX 7150 ICX 7550 ICX 7650 ICX 7850 ICX 8200
-
Downgrading a Stack to a Release Prior to FastIron 09.0.10a
Last Updated
Sep 03, 2026
, copy the old startup-config file you saved previously back to the ICX device. The following example downgrades an ICX 7550 device by copying the file named saved_startup_08095 from the server at the specified IP address and saving it as startup-config. ICX7550-48ZP Router# copy tftp startup-config
-
inline power poe-ha
Last Updated
Sep 03, 2026
enhancements that can be configured on ICX 7550 switches to allow brief or no power downtime. When configured, the PDs will not lose power while reloading and will have a brief power-down time when power-cycled. Configure the inline power poe-ha command before connecting the PD. If the ports are configured
-
vxlan-riot
Last Updated
Sep 03, 2026
RIOT. overlay-nhop-partition partition-size Specifies the overlay next-hop hardware partition size. Valid values are increments of 4000: 4096 (4000 entries), 8192 (8000 entries), 12288 (12000 entries), and 16384 (16000 entries). Global configuration mode VXLAN RIOT is supported for RUCKUS ICX 7550 and
-
PoE/PoE+ - Power over Ethernet
Last Updated
Sep 03, 2026
PoE/PoE+ - Power over Ethernet PoE/PoE+ - Power over Ethernet PoE/PoE+ - Power over Ethernet Feature Legacy inline power is not supported in 4-pair PoE ports. ICX 7550 ICX 7650 ICX 7850 ICX 8100 ICX 8200 Auto PoE firmware upgrade 08.0.95 08.0.70 No 10.0.10f 10.0.00 PoE enabled by default 08.0.95
-
Syslog
Last Updated
Sep 03, 2026
Syslog Syslog Syslog Feature ICX 7550 ICX 7650 ICX 7850 ICX 8100 ICX 8200 Syslog messages (RFC 3164) 08.0.95 08.0.70 08.0.90 10.0.10f 10.0.00 Enhanced Syslog headers specific to RFC 5424 08.0.95 08.0.70 08.0.90 10.0.10f 10.0.00 Real-time display of Syslog messages 08.0.95 08.0.70 08.0.90 10.0.10f
-
DHCPv6 Server
Last Updated
Sep 03, 2026
platforms for both Layer 2 and Layer 3 software images: RUCKUS ICX 7150 RUCKUS ICX 7250 RUCKUS ICX 7450 RUCKUS ICX 7550 RUCKUS ICX 7650 RUCKUS ICX 7850 For the DHCPv6 server to be enabled, you must upgrade to FI 08.0.90 using the Unified FastIron Image (UFI). Refer to the Software Upgrade and Downgrade chapter in the RUCKUS FastIron Software Upgrade Guide for more information.