  • Displaying system parameter default values

    Last Updated Sep 03, 2026

    32768 igmp-snoop-mcache 512 8192 8192 mld-snoop-mcache 512 8192 8192 The following shows an example output of the show default values command on a FastIron Layer 2 ICX 7450 device. device#show default values sys log buffers:50 mac age time:300 sec telnet sessions:5 System Parameters Default Maximum
  • speed-duplex

    Last Updated Sep 03, 2026

    command was introduced. 08.0.30g This command was modified to specify that the 1000-full setting mode is not applicable to 1G copper ports on the ICX 7250 and ICX 7450. 08.0.40 This command was modified to specify that on the ICX 7450-32ZP 2.5G ports, the command works in port pairs only. 08.0.40a
  • Displaying system parameter default values

    Last Updated Sep 03, 2026

    32768 igmp-snoop-mcache 512 8192 8192 mld-snoop-mcache 512 8192 8192 The following shows an example output of the show default values command on a FastIron Layer 2 ICX 7450 device. device#show default values sys log buffers:50 mac age time:300 sec telnet sessions:5 System Parameters Default Maximum
  • Bill of Materials

    RUCKUS ICX Switch Port Extender Deployment Guide

    Last Updated Sep 02, 2026

    have the same software image: FastIron 08.0.40 or later License Needed for Stacking N/A N/A A license is not needed. Products Used in ICX 7450 PE Ports Identifier Vendor Model Notes Switch/Units Ruckus ICX7450-24G ICX7450-24P ICX7450-48G ICX7450-48P ICX7450-48F ICX7450-32ZP PEs can be mixed with
  • Supported Software and Hardware

    Last Updated Sep 03, 2026

    Version Supported ICX 7150, ICX 7250, ICX 7450, ICX 7650, ICX 7750, ICX 7850, ICX 8200 FastIron 10.0.00 and subsequent release versions in the 10.0.xx code stream
  • show statistics tunnel

    Last Updated Sep 03, 2026

    display GRE-tunnel hardware counters on the RUCKUS ICX 7xxx series. 08.0.50 This command was modified to display IPsec tunnel information on the RUCKUS ICX 7450.
  • OpenFlow actions

    Last Updated Sep 02, 2026

    Clears all the actions in the action set write-metadata Writes the metadata field from the mask Brocade devices may support the actions listed in the following table. OpenFlow actions supported on Brocade devices OpenFlow action ICX 6610 ICX 6450 (Mixed stack) ICX 7750 ICX 7450 Process the packet
  • Multi-VRF Overview

    Last Updated Sep 03, 2026

    illustrates a generic, high-level topology where different enterprise functions are assigned unique VRF instances. Example High-Level Multi-VRF Topology A Multi-VRF instance can be configured on any of the following: Platforms that support untagged physical ports: Applies only to ICX 7250, ICX 7450, ICX
  • Configuring VRF system-max values

    Last Updated Sep 03, 2026

    Configuring VRF system-max values Configuring VRF system-max values Configuring VRF system-max values Use this example procedure to modify the default system-max values to accommodate Multi-VRF on a Ruckus ICX 7450. The default system-max value must be configured because the device does not have
  • show statistics tunnel

    Last Updated Sep 03, 2026

    display GRE-tunnel hardware counters on the RUCKUS ICX 7xxx series. 08.0.50 This command was modified to display IPsec tunnel information on the RUCKUS ICX 7450.