priority-flow-control
Last Updated
Sep 03, 2026
longer enables PFC on all ports. 08.0.60 Added a usage guideline concerning the support of this command and that this command is not supported on the Ruckus ICX 7150. 08.0.70 Added a usage guideline concerning the support of this command and that this command is not supported on the Ruckus ICX 7650. 09.0.10a PFC support was extended to ICX 7850 devices at the global level.
-
PoE/PoE+ - Power over Ethernet
Last Updated
Sep 03, 2026
PoE/PoE+ - Power over Ethernet PoE/PoE+ - Power over Ethernet PoE/PoE+ - Power over Ethernet Feature ICX 7150 ICX 7250 ICX 7450 ICX 7550 ICX 7650 ICX 7850 Auto PoE firmware upgrade 08.0.70 08.0.70 08.0.70 08.0.95 08.0.70 No PoE enabled by default 08.0.70 08.0.70 08.0.70 08.0.95 08.0.70 No Power
-
Syslog
Last Updated
Sep 03, 2026
Syslog Syslog Syslog Feature ICX 7150 ICX 7250 ICX 7450 ICX 7550 ICX 7650 ICX 7850 Syslog messages (RFC 3164) 08.0.60 08.0.30 08.0.20 08.0.95 08.0.70 08.0.90 Enhanced Syslog headers specific to RFC 5424 08.0.60 08.0.40 08.0.40 08.0.95 08.0.70 08.0.90 Real-time display of Syslog messages 08.0.60
-
system-max mld-snoop-mcache
Last Updated
Sep 03, 2026
entries supported is 512 by efault. num Specifies the maximum number of MLD snooping mcache entries supported. For ICX 7650 devices, valid values range from 256 through 8000. For ICX 7150 devices, valid values range from 256 through 1024. Global configuration mode For ICX 8200, ICX 8100, ICX 7850
-
Campus Fabric and IP multicast considerations
Last Updated
Sep 03, 2026
multicast considerations Unless otherwise stated, Layer 2 and Layer 3 multicast features supported on a standalone ICX 7650 are supported by the CB in a Campus Fabric domain, and the Layer 2 and Layer 3 scaling capacity are the same. An IP address cannot be configured on a PE port. Consequently, IPv4
-
Campus Fabric and IP Multicast Considerations
Last Updated
Sep 03, 2026
Multicast Considerations Unless otherwise stated, Layer 2 and Layer 3 multicast features supported on a standalone ICX 7650, ICX 7750, or ICX 7850 are supported by the CB in a Campus Fabric domain, and the Layer 2 and Layer 3 scaling capacity are the same. An IP address cannot be configured on a PE
-
DHCPv6 Server
Last Updated
Sep 03, 2026
platforms for both Layer 2 and Layer 3 software images: RUCKUS ICX 7150 RUCKUS ICX 7250 RUCKUS ICX 7450 RUCKUS ICX 7550 RUCKUS ICX 7650 RUCKUS ICX 7750 RUCKUS ICX 7850 For the DHCPv6 server to be enabled, you must upgrade to FI 08.0.90 using the Unified FastIron Image (UFI). Refer to the Software Upgrade and Downgrade chapter in the RUCKUS FastIron Software Upgrade Guide for more information.
-
Disabling Multicast Hardware Entry Optimization
Last Updated
Sep 03, 2026
oif-list and all keywords. device(config)# no ip multicast optimization oif-list all device(config)# no ipv6 multicast optimization oif-list all device(config)# write memory device(config)# exit device# reload Entry optimization is enabled by default on RUCKUS ICX 7150, ICX 7250, ICX 7450, ICX 7550, ICX 7650, ICX 7750, and ICX 7850 devices for Layer 2 and Layer 3 multicast traffic.
-
Load Sharing
Last Updated
Sep 03, 2026
Load Sharing Load Sharing Load Sharing Ruckus devices can load share among up to eight equal-cost IP routes to a destination. By default, IP load sharing is enabled. The default is 4 equal-cost paths but you can specify from 2 to 8 paths. On ICX 7650 ICX 7750, and ICX 7850 devices, the value range
-
SPX operation unit table
Last Updated
Sep 03, 2026
SPX operation unit table SPX operation unit table SPX operation unit table The following MIB table objects display SPX-related information for each operational CB and PE unit. The following table objects are supported only on the Ruckus ICX 7150, Brocade ICX 7250, Brocade ICX 7450, RUCKUS ICX 7650 and