OSPF - IPv4 Open Shortest Path First
Last Updated
Sep 03, 2026
OSPF - IPv4 Open Shortest Path First OSPF - IPv4 Open Shortest Path First OSPF - IPv4 Open Shortest Path First For considerations related to OSPF in an 802.1BR (SPX) configuration, refer to the Ruckus FastIron Campus Fabric Configuration Guide Feature ICX 7150 ICX 7250 ICX 7450 ICX 7550 ICX 7650 ICX
-
QoS - Quality of Service
Last Updated
Sep 03, 2026
QoS - Quality of Service QoS - Quality of Service QoS - Quality of Service Feature ICX 7150 ICX 7250 ICX 7450 ICX 7550 ICX 7650 ICX 7750 ICX 7850 Scheduling and queuing: Strict Priority (SP), Weighted Round Robin (WRR), Combined SP and WRR, 8 priority queues 8.0.60 8.0.30 8.0.20 8.0.95 8.0.70
-
xSTP - Spanning Tree Protocols
Last Updated
Sep 03, 2026
xSTP - Spanning Tree Protocols xSTP - Spanning Tree Protocols xSTP - Spanning Tree Protocols Feature ICX 7150 ICX 7150-ES ICX 7550 ICX 7650 ICX 7850 ICX 8100 ICX 8200 802.1s Multiple Spanning Tree 08.0.60 10.0.10d 08.0.95 08.0.70 08.0.90 10.0.10f 10.0.00 802.1s Multiple Spanning Tree enhancement
-
IPv6 Addressing
Last Updated
Sep 03, 2026
IPv6 Addressing IPv6 Addressing IPv6 Addressing Feature ICX 7150 ICX 7250 ICX 7450 ICX 7550 ICX 7650 ICX 7850 Global IPv6 address 08.0.60 08.0.30 08.0.20 08.0.95 08.0.70 08.0.90 Link-local IPv6 address 08.0.60 08.0.30 08.0.20 08.0.95 08.0.70 08.0.90 IPv4 and IPv6 host stacks 08.0.61 08.0.30 08.0.20
-
xSTP - Spanning Tree Protocols
Last Updated
Sep 03, 2026
xSTP - Spanning Tree Protocols xSTP - Spanning Tree Protocols xSTP - Spanning Tree Protocols Feature ICX 7150 ICX 7250 ICX 7450 ICX 7550 ICX 7650 ICX 7850 802.1s Multiple Spanning Tree 08.0.60 08.0.30 08.0.20 08.0.95 08.0.70 08.0.90 802.1s Multiple Spanning Tree enhancement (MSTP+) 08.0.60 08.0.30
-
ip multicast mcache-age
Last Updated
Sep 03, 2026
, ICX 7650, ICX 7450, and ICX 7250 devices. num Specifies the time, in multiples of 60 seconds, the device should wait before stopping traffic to a port when a leave message is received The range is 60 through 3600 seconds, in multiples of 60. Global configuration mode The no form of this command
-
Campus Fabric Scalability
Last Updated
Sep 03, 2026
7250, or ICX 7150 devices are used as PE units, 1,728 ports are supported. Campus Fabric domain maximum configuration can be summarized as follows: 4 CB units (ICX 7650, ICX 7750, or ICX 7850 stack) 32 ports per CB (32 X 4 for full CB stack) Maximum of 8 PE chains Maximum 16 stand-alone PEs (in
-
Campus Fabric scalability
Last Updated
Sep 03, 2026
7250, or ICX 7150 devices are used as PE units, 1,728 ports are supported. Campus Fabric domain maximum configuration can be summarized as follows: 4 CB units (ICX 7650 stack) 32 ports per CB (32 X 4 for full CB stack) Maximum of 8 PE chains Maximum 16 stand-alone PEs (in addition to 8 PE chains
-
Disabling the Flooding of Unregistered IPv4 Multicast Frames in an IGMP-Snooping-Enabled VLAN
Last Updated
Sep 03, 2026
following platforms: RUCKUS ICX 7850 (standalone, stacking and SPX stack configuration) RUCKUS ICX 7750 (standalone, stacking and SPX stack configuration) RUCKUS ICX 7650 (standalone, stacking and SPX stack configuration) RUCKUS ICX 7550 (standalone, stacking and SPX stack configuration) RUCKUS ICX 7450
-
Switch Port Extender and IP Multicast
Last Updated
Sep 03, 2026
header are used to identify a single PE port or a set of PE ports. For details on SPX configuration and terminology, refer to the RUCKUS FastIron Campus Fabric Configuration Guide. SNMP support RUCKUS ICX 7650 or ICX 7750 devices can be used as the Control Bridge (CB) for an SPX system. PE units