Overview of ICX Switch Management
Last Updated
Sep 22, 2026
in the DNS server with the hostname ruckuscontroller or ruckuscontroller. local domain that points to the SmartZone IP address. On ICX 7250, ICX 7450, and ICX 7750 devices, self-signed certificates are used. SmartZone honors these certificates when the non-tpm-switch-cert-validate command is entered
-
lldp advertise port-id-subtype
Last Updated
Sep 03, 2026
ethernet 1/2/2), or you can combine a range with a list (for example, ethernet 1/1/1 to ethernet 1/1/4 ethernet 1/1/1 ethernet 1/1/2). Global configuration mode The port ID subtype to advertise is only configurable on and ICX 7750, ICX 7450, and ICX 7250 devices. The LLDP port ID subtype advertises
-
sflow sample
Last Updated
Sep 03, 2026
resources. Using a low denominator for the sampling rate can cause high CPU utilization. On RUCKUS ICX 7750, ICX 7450, ICX 7250, ICX 7650, ICX 7850, and ICX 7550 the CPU-bound sFlow sample packets are rate-limited to 50 samples per second to avoid high CPU utilization. The sampling rate must be set
-
Overview of ICX Switch Management
Last Updated
Sep 03, 2026
< SmartZone_Control_IP_Address > Add an entry in the DNS server with the hostname ruckuscontroller or ruckuscontroller.<local domain> that points to the SmartZone IP address. On some ICX 7250, ICX 7450, or ICX 7750 devices, self-signed certificates are used. SmartZone honors these
-
Stacking
Last Updated
Sep 03, 2026
Switch Port Extender technology, which is based on an ICX 7650, ICX 7750, or ICX 7850 core stack. Refer to the Ruckus FastIron Campus Fabric Configuration Guide for more information.
-
Adding New Links between Existing Stack Units
Last Updated
Sep 03, 2026
configure the multi-stack-port or multi-stack-trunk command to change both ends of the live link at the same time. For example, suppose you have an ICX 7750 stack with a live link stack-trunk 1/2/1 to 1/2/3 connected to stack-trunk 2/2/4 to 2/2/6. After removing the unwanted cables between ports 1/2/3 to 2
-
Last Updated
Aug 20, 2026
RUCKUS ICX Switches
Product Guides
Install and Upgrade
stack............................................................................................................................................................................. 130 ICX 7750 stack configuration overview
-
Campus Fabric Topology Overview
Last Updated
Sep 03, 2026
ICX 7650, ICX 7750, or ICX 7850 units connected in a linear or ring topology. PE units are specially configured ICX 7450, ICX 7250, or ICX 7150 units that are connected to the CB. The PE units can be connected to each other over a single SPX port or LAG to form a PE chain or ring. The PE chain or
-
Flow table entries
Last Updated
Sep 03, 2026
Matching precedence of the entry Counters Statistics for matching packets Instructions Action set or pipeline processing Cookie Opaque data sent by the OpenFlow Controller RUCKUS ICX devices support the OpenFlow match fields in the following tables. OpenFlow match fields for ICX 7750 and ICX 7450
-
sflow sample
Last Updated
Sep 03, 2026
that you do not change the denominator to a value lower than the default. Sampling requires CPU resources. Using a low denominator for the sampling rate can cause high CPU utilization. On RUCKUS ICX 7750, ICX 7450, ICX 7250, ICX 7650, ICX 7850, and ICX 7550 the CPU-bound sFlow sample packets are